  1. hugop973

    Grounding Ring Size

    Hi, I need your input to understand correctly the way of sizing the grounding ring. Ground Ring not less than 2 AWG Cu per NEC. I worked in a design of an industrial building with 3,000 A service, the ground ring that encircle the building was spec 4/0 and have not received comments on that...
  2. hugop973

    SKM

    I need to represent two low voltage circuit breakers mechanically interlocked, N.C. and N.O. respectively. How do you simulate this with SKM software ? Thanks
  3. hugop973

    Data Center in close proximity to a 115KV Substation

    Is there a minimum separation recommended between a Data Center and a 115KV Substation. The Ground Potential Rise in an existing Data Center adjacent to a 115KV substation (wall to wall) is 809V, there's a concern about the EMI affecting the performance of the servers, routers, etc. GPR of 809V...
  4. hugop973

    Computer Program for Electric Utilities

    What are the advantages and disadvantages of computer programs PSSE, ASPEN, and IDRAW. Thanks
  5. hugop973

    500MCM or 600MCM?

    Hi, I have a question about handling 500MCM and 600MCM cable, CU. Can you tell me which one is easier and/or preferred by contractors. Thanks
  6. hugop973

    Switchboard

    Hi, A question about a switchboard rated 3,000 Amps, 480V, 3 phase. When we say in our drawings that the equipment is 3,000 Amps, the manufacturer always provide the equipment with the busbar rated 100% or we have to specify in our drawings, that the bar is "3,000 Amps, 100% rated". Thanks for...
  7. hugop973

    Automatic Transfer Switch

    Hi, I have a question about an automatic transfer switch, 3000A rated with bypass. Can you tapped an additional load off the load terminal of an automatic transfer switch? Is that legal? Thanks
  8. hugop973

    Transformer Protection

    I have a Secondary Unit Substation, the transformer is rated 2500 KVA, 13.2KV Primary - 480V Secondary, 3 phase. I was providing overcurrent protection and differential protection to the transformer but other engineer eliminated the differential protection because he said is too expensive and...
  9. hugop973

    Load Interrupter Switch for Medium Voltage Generators

    I have 4 medium voltage generators (13.8KV) connected to a paralleling switchgear. The generator's manufacturer is recommending to use a load interrupter switch, SF6 type, rather than a simple safety disconnect switch on each generator. I know that the circuit breakers in the paralleling...