thread378-456875
I have been involved in the R&D of tees design for pipeline and plant application in the 80s and 90s. We developed parametric equations to work out range of header and branch thickness for high yield steels, but the manufacturers could never produce tees for say X65 strength...
We have some structural steel parts made of 304 and 316 stainless steel below the jetty deck in the splash zone. Should we protect these s steel parts with the cathodic protection system (using anodes) installed for the jetty piles which are c. steel.
Thanks in anticipation.