Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: KirkGH
  • Content: Threads
  • Order by date
  1. KirkGH

    Special Inspections for 5/16" or less fillet welds

    The 2009 IBC states 1704.3 Exception 2.1 that Single pass fillet welds not exceeding 5/16" in size do not require continuous inspection. Since IBC defers to AISC 360-10 Chapter N I can't find an exception to continuous special inspections for small fillet welds in Chapter N. Can somebody help...
  2. KirkGH

    Cable Analysis for a Backstop Net

    I've read through the posts on cables and gathered that the most appplicable equation to use to analyze the the attached schematic is wL^2/8=TH. T = tension in cable H = amount of sag in cable The attached diagram shows the support for a net suspended over some bleachers. The net spans 6 feet...
  3. KirkGH

    ASCE 7 Ice Load Provisions for Netting

    I need to figure out the ice load on some netting but am getting a nnumber that can't be correct. The equations are straight forward. ASCE 7-10 by the way. t = 0.5" Vc = 30 mph temperature = 15 degrees Farenheit Kzt = 1.0 Ii = 1.0 Dc = .0945 in. Per 10.4-4 fz= 0.980 Per 10.4-5 td = .98 inches...
  4. KirkGH

    HSS Column Selection for 4 Story Structural Steel Building

    I've been tasked with designing columns for a 4 story building (interior columns only, the perimeter is concrete tilt wall). Story Height: 15 feet Floor: Vulcraft VLI composite slab/metal deck with open web steel joists and wide flange steel beams. Roof: Metal Deck Column Shape: Square HSS...
  5. KirkGH

    Cold Formed Steel: Simple Clip Beam Connection Design

    For architectural reasons it's better to turn the cees in the direction shown in the attached document. My concern is buckling of the clip angle. Is this wise? How do I calculate the capacity of the clip? As best I can tell I could approximate the condition conservatively as a cantilever to get...
  6. KirkGH

    WRI/CRSI Design of Slab-on-Ground Foundations Deflection Calculation Example

    Does anybody have an example of the deflection calculation for WRI/CRSI Design of Slab-on-Ground Foundations method? I've got a company spreadsheet that had errors and is now (conceivably) corrected and I want to verify my results with a worked out example but can't find one. The calculation, as...
  7. KirkGH

    IBC - Stair Guardrail / Handrail Requirements

    I'm working with a client who had code enforcement tell them their stair handrails needed to be "brought up to code." My interpretation is that any and all modifications need to be made to meet IBC 2009 (current city adopted code). My client thought that just meant adding pickets to create a 4"...
  8. KirkGH

    Repair of Corroded Tube Column Bottom and Base Plate

    This is an existing building with a column in need of repair. The remaining rust can be scraped and corrosion inhibitor applied. A nearby drain outlet is the cause and will be dealt with. The column is HSS 6 x 6 and supports about 53k (D+.25L) at the moment. W 16 x 26 beams frame into each side...
  9. KirkGH

    Existing Steel Stair Assesment: Rivet and Bolt size vs. head dimension?

    I'm assessing an existing 4 story fireescape stair. I can't get an exact year of construction, but based on the evidence presented we're going to assume 1927. I measured the heads and diameter where I could and here's what I'm left with. Bolts (square head): .394"dia. .... head ... dia...
  10. KirkGH

    ACI Crack Repair Requirements

    I've been told by my supervisor to "keep looking" for ACI requirements and guidance regarding crack repair vs. crack width (i.e. what width or circumstances require repair?) when I've found none. I've look in ACI 318-08 and the closest guidance I can find is 20.5.3 and 20.5.4. that would...
  11. KirkGH

    Cutting Existing 4 x 2 Wood Floor Trusses and Repair Guidance

    I'm cutting a couple of existing floor trusses down from 15 ft to 10 ft to create head room for a new stair in a residence (replacing trusses with new LVL or similar is is not possible because there are air ducts in the way). My planned repair is to toenail 3 vertical 2x4 at the end as...
  12. KirkGH

    60 FT SPAN IRON/STEEL PIPE WITH 3 - 20 FT SECTIONS

    Task is to design a 60 ft span, simply supported, pipe using 20 ft sections and mechanically fastened connections (flanged pipes) to create fixity. I was looking to DIPRA website for guidance, but the "ductile iron on supports" brochure only supports 20 ft sections with 20 ft support...

Part and Inventory Search