  1. struct6

    transportation and handling loads.

    Hi all, Can some one tell me what kind of lateral load combination should I use for analyzing a structure subjected to transportation and handling loads. The structure is a skid which will be installed in a chemical processing plant. It will be built , assembled off site and transported to it...
  2. struct6

    latreal loads due to handling and transportation

    Hi all, Can some one tell me what kind of lateral load combination should I use for analyzing a structure subjected to transportation and handling loads. The structure is a skid which will be installed in a chemical processing plant. It will be built , assembled off site and transported to it...
  3. struct6

    transportation and handling loads

    Hi all, Can some one tell me what kind of lateral load combination should I use for analyzing a structure subjected to transportation and handling loads. I saw in a sample calculation that they used the following combinations for lifting and handling loads respectively, a. for lifting load...
  4. struct6

    shear stud location on a composite beam

    On a composite slab the contractor welded the studs to the edge of the flange rather than the center of the beam. Moreover he poured the slab before we looked at it. My question is, now since the studs are welded off center will this reduce the capacity of my composite beam and is it written...
  5. struct6

    how to check the number of studs welded to a beam in a composite slab

    Hi All, We want to verify if the contractor has installed the correct number of studs on a beam in a composite slab system. They poured this particular area before we inspected and now the owner want us to make sure that the contractor installed the studs as per our drawings. Anybody has got...
  6. struct6

    Will the snow load drifting double up at corner ?

    Hi Folks, what I have is a sloped lower roof which is surrounded by higher roof area along the north and east side. I calculated the drift width and drift load which is 6 ft and 30 psf respectively. my question is will the drift load be doubled up at the north east corner ? Thanks
  7. struct6

    base isolation of slab

    Hi All, I am working on a project in which the client wants to put a high sensitive equipment in a ground floor of the building. they have conducted a vibration survey and the current vibration levels are higher then the acceptable levels established by the equip manufacturer. The current...
  8. struct6

    Insulation required for frost protected shallow foundation

    Hi Folks, I am designing a foundation for a unheated storage unit. I am planning to use a slab on grade system with thickened edge. My question is 1. should we provide a continuous insulation layer under the entire slab or should we insulate only at the edge of the wall and extende it out a...
  9. struct6

    Is S.E. License required to practice in Nevada and Alaska?

    Hi all, Our firm just got some RFP's for industrail ( pipe racks, catwalks,etc.) projects to be located in Alaska and Nevada. The principals of our firm are registered civil engineers in many states in the US but not Nevada or Alaska. They are planning to get registered as a civil engineer in...
  10. struct6

    ringwall footing

    I am designing a ring wall foundation for a tank which is 32 ft tall and 22 ft dia. I have designed the ring wall itself and now working on the footing part of the ring wall. I am planning to use a 4 ft wide footing. Since this footing will have both axial load and lateral moment due ti wind i...