  1. KZ001

    stratification question

    Hi, Does anyone know if comfort is a requirement in the latrines and shower areas? Can you allow some stratification?
  2. KZ001

    Calculation of converging bullhead tee

    Hi, How do I calculate the pressure loss of a converging bullhead tee in a return duct system. The tee has dimensions 23"x23" for the main duct and the branch. Thank you!
  3. KZ001

    Plenum return pressure drop (HVAC)

    Hi, I would like to calculate the return air pressure drop through a plenum between the first and second floor of a building. The building 1st and 2nd floors shear common plenum return. Do I have to take into account the pressure drop of every single return grill on the ceiling of the first...
  4. KZ001

    HVAC question

    Hi, I am designing a HVAC system for an equipment room that houses a large electrical apparatus. The load in the room can vary from 10,000Btu/h to 85000Btu/h. The room area is 1345ft^2. Should I use CAV or VAV box?
  5. KZ001

    HVAC Climatic Design

    Can someone define “coincident 1% outdoor ambient dry-bulb temperature”? Thank you!
  6. KZ001

    Ventilation requirements for non-occupant area

    Hi Everyone, I have to condition a space which would be classified as non-occupant area. WSHP will be used for cooling and heating of that area. Do I have to provide an outside air for a space that will not be occupied at all? Equipment in the space requires conditioning of the area. Thank you!
  7. KZ001

    Closed loop chilled water system

    Hi, Can someone help me with the following questions? 1.Is the minimum system pressure equal to the system static head (elevation)? 2.Does the system expansion tank precharge pressure have to equal the system minimum pressure? 3.Is it better and more conservative if the expansion tank...
  8. KZ001

    shell-end-tube heat exchanger

    I am designing a shell-end-tube heat exchanger. My shell is a rectangular water tank and my tubes are 1.5in stainless steel pipes. In my design I will not use baffles. The only problem I am facing is calculating the shell-side heat transfer coefficient h(o) (the heat transfer coefficient outside...
  9. KZ001

    Resistance coefficient for pipe fittings

    I need to determine a resistance coefficient for pipe fittings. The data I found in the web shows different values for resistance coefficient (K). What is the best source providing the most accurate data? Sending a link would be very helpful. Also, do PVC fittings and Steel fittings have...