  1. koplan

    More powerful and functional Compress than PVelite

    I use both s/w. Supreme program will be of mixed one of both softwares. The compress is more cnovennient but less functional than othe program. I'd antipate next build of compress to be big changed and reflected with user's requirements so far and further, considering the merits of pvelite...
  2. koplan

    Waiting for Div.2, 2007 Ed.

    Waiting for release of Compress with big changed Div.2 (ASME 2007 Edition)..................
  3. koplan

    Tailing Lug shape

    In present compress, the shape of tailing lug is square type. In almost case, the end part of lug is of round type. Please reflect it next build. Thanks a lot.
  4. koplan

    When issue the new version of Compress?

    Hi, It's long time since the last build (#6258) of compress. When I can meeet the new build? Thanks for ALL THE STAFF of COMPRESS.
  5. koplan

    Another Design SoftWare

    I provide the software for vertical vessel design program for free. It's my own program. But it's stopped on ASME Section VIII, Div.1 1998. Please refer to attachments.
  6. koplan

    Local stress check for Nozzle on Blind Flange

    So often, The nozzle located on blind flange need to be analysed the local ctress per WRC. Have any method to do this...? Thanks a lot.
  7. koplan

    Skirt large opening calculation

    Hi, Many customers require the strength calculation for skirt opening (for access) with skirt section stress. Please consider these activities next time.. Thanks.
  8. koplan

    2" 150# LWN thickness?

    Dear, everybody!!! I found the the property of 2" LWN size someting wrong as follows. Please review the database. ================================================= per ANSI; OD = 3.25"82.55mm), ID=2" (50.8mm), thickness = 0.625" (15.875mm) per Compress; OD = 77.72 mm, ID = 50.8 mm...
  9. koplan

    Loading data summary?

    Moment and shear force for each load and new/corroded condition shall be shown. Especially in the saddle type, no wind load is shown clearly. Why...? I think it's so simple.
  10. koplan

    Weight assign

    Weight for insulation clips and/or tray support rings in the input shall be included in fabrication weight regardless to condition. But there are no mentioned anywhere.
  11. koplan

    Weight summary?

    Many customers request the weight break-up list. In compress, the weights for shop test and field test condition are very ambiguous. And center of gravity shall be done in each condition.
  12. koplan

    Why not do field rehydro test in corroded condition?

    Field hydrotest is done in new condition. But almost and usually, it's needed to ensure the safety for corroded condition not new in field.