Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: yoyoe
  • Content: Threads
  • Order by date
  1. yoyoe

    Motor pulling higher then rated amps.

    I have a diecast machine with two 30hp three phase motors running 460 volts. Nameplate rating on them is 37.5 amps. Under load they each pull 40-43 amps. What I would like to know is this normal? I also have a problem with blowing the main fuses, LPJ 100 Sp. Amp meter says total amps through...

Part and Inventory Search