  1. SaCaZu

    Minimum thicknesses between Elbows and Straight Pipe

    Greetings, ...I'd like to know if exists some criterion that let me say that the allowable minimum thickness in an elbow must be greater than allowable minimum thickness in a straight pipe for its replacement due to that the elbows are points with erosion rate higher than straight pipes...
  2. SaCaZu

    Coatings vs H2S

    Greetings I'd like to know if any of you has had some experience, tryin' to get an appropriate coating that can inhibit this kind of aggressive environment inside oil storage tanks based on carbon structural steel places (ASTM A-36). Any answer or suggestion is welcome Thanks in advance.
  3. SaCaZu

    Oil Storage in Pits

    ...Greetings Friends. I'd like to know if there's some international code that forbids the usage of pits to store oil. Thanks in advance.
  4. SaCaZu

    Requered Minimun Thickness en Plates

    Greetings. ..What minimum thickness should I use to decide that plate is refused or not? For Example, If I'm testing a 1/4" plate from outside drum of a boiler (Mitchell, 11 ton), could I refuse a plate when its thicknesses are equal 50% or below this one? is there some code that lets me know...
  5. SaCaZu

    Question about Tank Repair

    Greetings If I'm going to repair an oil tank who owns localized pitting in its first plate and I decided to install a plate on this one. where should I put this plate, in or outside of tank shell? thank in advance.
  6. SaCaZu

    Wire Rope and Stack.

    Greetings. I'm lookin' for some code or specification that indicates how to select the diameter and longitude from an wire rope according to stack height installed an oil-field heaters. I know that there's calculations which take some variables like wind velocity, but is there any code that...
  7. SaCaZu

    Heat Exchanger (Steam and Oil)

    as The tittle indicates it... Is it logical to think that the steam shall always flow outside tubes if its purpose is to warm the oil? Does TEMA support it? I guess that the steam flows by outside due to its high temperature and pressure. I don't know if I'm wrong but I believe to...
  8. SaCaZu

    Doubt about Hydrostatic Test in API 653

    Greetings. 1.- When does API 653 explain about Hydrostatic Test (Section 4.3.3.2), it's mixing terms between Hydrostatic and Neumatic Test in one or the hydrostatic test'll be used without internal pressure like if it was an atmospheric tank? 2.- is It correct to completely fill until the...