Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: justint
  • Content: Threads
  • Order by date
  1. justint

    Web Design and Process Control

    Hi I work with PLC and SCADA applications. Reacently we have been looking at monitoring our systems remotely, changing and monitoring variables via SMS, remote access to HMI etc. I have been thinking strongly about making a web page that would allow me to display and alter variables from any...
  2. justint

    Septicity Dosing guidelines

    Hi We are in the process of designing a septicity dosing system for a waste water pumping station to reduce the H2S04 further up the rising main, we are planning to dose with Nutriox (calcium nitrate) From looking at existing systems I can see that the inputs to the system are mainly the level...
  3. justint

    Electrical power question

    Hi Im involved in a project where I am setting up a system to remotely monitor the energy consumed by a industrial plant with a number of motors, pumps etc. Im in Ireland. I have gotten to the stage where I can send a CSV file each hour that lists the instantaneous KW, KVA, KVAR, power factor...
  4. justint

    Yaskawa Drive

    Hi I have come across Yaskawa J1000 family of inverters and am considering purchasing one to control a pump on a variable frequency. I have read a few posts in this forum where the voltage used was slightly different to the rating of the inverted and this led to over excitation and tripping...
  5. justint

    Capacitor size for motors

    Hi Is there a calculator or rule of thumb to use for selecting start and run capacitors for single phase inductance motors if i know the supply voltage and current ratings for the motor. I normally refer back to the manufacturer but was hoping for an alternative method. Justin
  6. justint

    Sump pump with small flow rates

    Hello Im searching for a pump for lifting water from a sump through a filter. The max distance to lift is 1.5 metres and the filter requires another 0.2 bar of suction. I require a pump with suction head of 4 metres but the flow rate must be kept at 70 l/hour. Does anyone have any...
  7. justint

    UltraSonic Level Sensor

    Hi does any one know of a competitively priced Ultrasonic level sensor that will provide a 4-20mA, 0-5v or 0-10v output for use in a PLC? The sensor application is for waste water and will be used on sump tanks of max depth 10 metres. Thanks Justint
  8. justint

    Conductive level probe query

    Hi Has anyone ever heard of a conductive level probe that is based on one probe only with incremental pairs of contacts at levels along the probe? I know such a device exists but any search string results in probes with 2 or more electrodes or pendular probes. Any help appreciated Justin Trainor

Part and Inventory Search