  1. jwparker

    Humidifier MCA / MOP

    Im trying to determine the correct MOP for a commerical humidifier. The unit is 51kW. If i go by my standard motor calculations by the tables in the CEC i get an MCA 77Amps and MOP 175Amps. Is a humidifer calculated differently than a regular motor?
  2. jwparker

    CT Sizing

    Im curous about CT sizing for a 347/600V service entrance. It being 600A 100% rated, would a 600/5 CT become saturated near the full 600A mark? Would this application require a 800/5 CT instead?
  3. jwparker

    Computer Receptacles

    Is it really necessary for computer recpetacles to have dedicated neutrals? Is it because of switch mode power suplies overloading the neutrals? I cant see it being for power quality..?
  4. jwparker

    Electrical Room Loop Ground

    Anyone know the specs on the size of a electrical room loop ground? I cant seem to find the size of bus required. There's around 4000A fault current at 12.47kV. Im thinking its around 50 or 75mm by maybe 5mm copper bus.
  5. jwparker

    Substation Grounding

    I realize this is a multi-directional complicated topic however I'm looking for a 'next step' in my design. The design revolves around replacing some oil-filled pole top transformers with a unit substation. The capacity is increasing from 1100kVA to 2500kVA. We are using a wye-grounded to...
  6. jwparker

    15kV Fuse

    Im trying to spec a 12.47kV load break switch with a 600A fuse, or close to it. Finding the 600A switch is easy but I cant seem to find a 600A fuse/fuse holder. Only 540A but requires 800A holder, what am I missing?
  7. jwparker

    Cable Weight

    Does anyone have any information regarding cable weight by the foot, I need to know how much copper 750mcm cable runs will be.
  8. jwparker

    magrini galileo circuit breakers

    Im attempting to obtain information regarding setting the LSI settings on magrini galileo circuit breakers. Has anyone ever used/heard of these before? Specially type MG. I know this is a shot in the dark.
  9. jwparker

    Data Communication Rack Bonding

    I've attached a rough sketch of a communications riser for a school design Im working on. I'm questioning if the bonding layout for my racks is appropriate. Specifically if its required to bond each rack to its respective building steel, of if I should keep a isolated ground back to the main...