  1. Fatalxception

    AISC provisions

    Under IBC 2000, do you have to design and detail according to AISC 97 seismic provisions when R>3 (example eccentrically braced frames), even if you are in seismic design category C?
  2. Fatalxception

    Concete Expansion Joints

    I always think about control and construction joints in concrete slabs and walls but not expansion joints. When are you supposed to put in expansion joints?
  3. Fatalxception

    Expansion joints/Seismic joints

    Is everybody else allowing enough of a gap in roof thermal expansion joints (example in single story metal deck) to satisfy the seismic joint code requirement as well. I don't usually see this done. Since the buildings are acting separately perpendicular to the joint, I think a seismic joint...
  4. Fatalxception

    Locking autocad toolbars

    Is there a way to lock all the current toolbars on my screen so that they can't get accidentally moved around or turned off?
  5. Fatalxception

    ACI 530 and unity equation

    When using ACI 530, if the wall is reinforced you only have to check fa/Fa + fb/Fb <1.0 (or 1.33) for the masonry if the axial stress in the wall is greater than the allowable axial stress if the wall was unreinforced. If it isn't, you can directly add the axial and bending compressive...
  6. Fatalxception

    Rigid Diaphragm and Bracing Loads

    I have a 3 story building that uses the same steel brace size and configuration for it's lateral resistance(wind) from top to bottom, and has conc. floor diaphragms. On the 3rd floor there is for example 3 braces (one on each end of the bldg. and one in the middle of the building). On the...
  7. Fatalxception

    &quot;Minor storage facility&quot;

    When using the Florida Building Code, when does a minor storage facility no longer considered minor? Is there a certain size of facility that matters? I am specifically asking in regards to wind load importance factors. I also looked in ASCE7 and did not find any help there either.
  8. Fatalxception

    illinois SE exam

    If you have a PE license in another state, what is required to be able to take the SE exam in illinois? Does your work history have to be under a licensed SE?
  9. Fatalxception

    Background Color

    Can you change the background color for the output screen to something other than white?
  10. Fatalxception

    Vertical Loads

    On page 59 of the april edition of modern steel construction magazine, does anyone know why the flat roof snow load is multiplied by cos^2 instead of just cosine to get the sloped roof equivalent, like the dead load?
  11. Fatalxception

    Beam shear

    Does anyone know why you can neglect the shear in concrete and wood beams that occurs up to a distance &quot;d&quot;(depth of member) from the face of the support but you cannot do this with steel beams?