Dear All,
Can you help!!
habitually we fabricate Clamp Ferrule using Rod Bar SA-479-316 for 4" dia. and less, UG-14(b)does not accept this material for 6" dia.I think to use piping material: SA-312-TP316 , So I can machine 6" pipe Sch80 to obtain 6" ferrule.IS IT CORRECT TO USE THIS MATERIAL...
Dear All,
habitually we fabricate Clamp Ferrule using Rod Bar SA-479-316 for 4" dia. and less, UG-14(b)does not accept this material for 6" dia.
I think to use piping material: SA-312-TP316 , So I can machine 6" pipe Sch80 to obtain 6" ferrule.
IS IT CORRECT TO USE THIS MATERIAL. IF NO WHAT...
Hi,
I'm designing a SS bolted flange for agitator support on the top head of the vessel , this flat flange will be simply welded to top head,it has 8.5 in OD, 4.5in ID, 1 in Thk, and 6 Bolt hole of 9/16 in dia. with 6.5 in Bolt circle dia.
2 questions:
1- can I use plate material for this not...
Hi,
I'm designing tank on unbraced legs to seismic and wind load according to UBC 97, the project location is outside US, exactly in middle east region, Could some one help :How can I get the seismic Map of other countries, and all parameters, soil type, wind speed, ..etc.
Thank you.
Laurent.
Hi,
I have to design a storage tank containnig LIQUID CO2,
to ASME sect VIII div.1 ,MAWP 350psi, MDMT -40 deg.F, 8'dia., 26'H.Matl'S: SA-612,
I started to get physical properties of CO2,in order to determine the optimum operating (Temp., pressure).and reading some technical documents related to...
Hi,
did some one know this situation:
I have to recalculate the reinforcement required for a 24" Nozzle on Head taking in account a new loads ( caused by piping loads), the vessel is already in shop,
the first calculation ( without new loads)require a pad
( 4" x3/8")as reinforcement, this pad...