  1. Lmarcano

    [b]ASME Section I, NDE & Qualification for Strenght T/TS Welds[/b]

    Hi, friends. We experienced recently a recurrent leak problem with tube to tubesheet welding joints in a sulfur recovery unit waste heat boiler (firetube, Rentech). After 4 years in every shutdown (cooling) welds began to leak, we made several repairs before take a decision to retube.Tube...
  2. Lmarcano

    Galvanic Anodes For Sumersible Pump

    Good afternoon gentlemen, recently here in our plant was carried out maintenance works of some vertical submerged pumps VTP type, those equipment run with Effluent Water and was manufactured by Ingersoll-Dressser, the bowls and the column pipe are carbon steel, It shows moderate External...
  3. Lmarcano

    Nafta Hydrotreating: Hydrogen Blistering in A106 GrB pipe?

    Hi, recently we carried out a thickness measurement of a PIPE by ultrasonics and find low values respect to the nominal, the problem, hidrogen blistering of a 12 months pipe, probably the pipe was inadecuate A53. Now the question is, what is the better method or test in order to differentiate a...
  4. Lmarcano

    Nafta Hydrotreating : Hydrogen Blistering in A106?

    Hi, recently we carried out a thickness measurement of a PIPE by ultrasonics and find low values respect to the nominal, the problem, hidrogen blistering of a 12 months pipe, probably the pipe was inadecuate A53. Now the question is, what is the better method or test in order to differentiate a...
  5. Lmarcano

    Control Valve Repair: The pressure test

    What is the applicable code to support a pressure test after welding repair in a control valve body. We review ASME B16.34a but this code refers to New valves, Can we use this procedure? Do you know another code or practice more specific? I think that is not convenience use it (B16.34b) because...
  6. Lmarcano

    Pressure Test for a Control Valve Repair Body

    What is the code applicable for pressure test of a control valve repair body? I was rewiewing the B16.34a but I don't read nothing about "repairs". It's reasonable performance a test pressure with the procedure for a new valve?