  1. julesm

    Asym L-L, Sym L-L, L-G Fault Data (?)

    Greetings, I have received available fault current data from the utility in the form of L-L instead of Three phase. I have not seen this before from my local utility. I am wondering if this is a mis-speak because I was given this data third hand. I have not been successful reaching the utilty...
  2. julesm

    21kV Relay Coordination with Utility (PG&E)

    Greetings - I need to select coordination settings for a Basler BE1-51 between the PG&E SEL-251 and the (5) Cutler Hammer RBA-400 125E fuses for the 5 substation feeds. I am confused by the info from the utility. Here is what I was given: Relay = SEL-251 CTR = 1200/5 Ground: curve = VI, T = 1...
  3. julesm

    SKM 208V calculated sc current too low. Any ideas?

    Hello and help. My sc report results don't make sense. I have a 3000A 480/277V building with utiltiy reporting 51k AIC. For some reason all the 208V fault currents are calcuulated in the 500A range. When I model the 208 v portion separately, the results are in the 5000A range. Any ideas whate my...
  4. julesm

    skm modeling of 250' bus duct

    Greetings! I am performing a short circuit and arc flash for a multi-story building with 4000A 480V busduct risers. Each floor has several plug-in breakers. Do I model this busduct as one long bus or each "floor" is it's own bus? I just need to err on the conservative side for a preliminary...
  5. julesm

    new vs existing/retrofit office bldg

    (E)400A-1P service. Office bldg being "mostly gutted". (E) and (N) lighting and rcpts to be added to 2 new panels. 2 (E)panels to remain have HVAC & misc. Do I treat this as "new" or "addition"? Any guidance is so appreciated!
  6. julesm

    Cable Damage curves vs coordination

    I'm trying to coordinate breakers using SKM software. I don't understand how the cable damage curves come in. Aren't cables damaged in more of an long-term heating "overload" situation and not in the .1 or 1.0 second range? I actually have not considered cable damage before so I would love some...
  7. julesm

    MCA vs MOCP vs FLA vs LRA

    It's been a while so I'd appreciate some help. What is the difference between and the significance of MCA (minimum current ampacity) MOCP (maximum overcurrent protection) FLA (full load amps) and LRA (locked rotor amps)? I've got a chiller with MCA, MOCP, and RLA and a ac unit eith FLA and...
  8. julesm

    750kW standby generator loading

    How many amps can I put on this 750kW cat? Manufacturer uses 0.8 as power factor. My 480V building is at 0.95 power factor. 750kW/0.8 = 937kVA 750kW/0.95 = 789kVA Building Load is 1020A. 1020 X 480V X root3 x 0.95 = 806kVA So, one guy says use the 937kVA rating because the bldg pf is .95...