Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: FTank
  • Content: Threads
  • Order by date
  1. FTank

    E-Tank Software

    I suggest trying its@innovativetanksolutions.com before deciding.
  2. FTank

    Storage Tank Foundation Settlement

    I would appreciate hearing from anyone that has had experience in storage tank settlements, both uniformly & differentially.API 650 doesn't address this very much that I can find other than:Par. 5.10.4.7 d. "The columns shall be effectively....in the event of vertical movement of the columns...
  3. FTank

    Tank Foundation Settlement

    I would appreciate hearing from anyone that has had experience in tank settlements, both uniformly & differentially. API 650 doesn't address this very much that I can find other than: Par. 5.10.4.7 d. "The columns shall be effectively....in the event of vertical movement of the columns relative...
  4. FTank

    API 650 11th Edition Addendum 1

    Is anyone aware of Addendum 1 to the 11th edition having been issued yet? The "grapevine" advises that this was supposed to be issued by the end of 2007?
  5. FTank

    Drain Dry System for conical floor tank.

    Has anyone had experience with a "drain dry" system for a conical floor storage tank. I believe the idea is to slope the tank floor to the center and run an outlet pipe from the side of a sump which would be installed at the low point of the cone, thru the tank pad (sand & gravel construction)...
  6. FTank

    API 650 Eleventh Edition, May 2007 Proof 2

    Has anyone heard via the "grapevine" as to when this edition is going to be released. I'm presently working on a new storage tank specification that references API 650 and since there are so many changes including "bulleted" paragraphs in the May 2007 Proof 2, I don't want to draw-up and issue a...
  7. FTank

    Please offer your opinion

    If you are in possession of a draft copy of API 650 Proof 1 January 2007 - refer to: 3.1.5.2 under Vertical Shell Joints par b. - "shell courses shall be flush-stacked on the inside" 3.1.5.3 under Horizontal Shell Joints par b. - "abutting shell plates at horizontal joints shall have a common...
  8. FTank

    Addendum 4 3.11.2 Confusion

    Has anybody figured out why the 2nd criteria formula has to be satified? Once you have satified 1st criteria (formula) what's the point in calculating the liquid moment. Example: 20' Dia. x 40' Shell height Tank. Design Pressure: 6" H20; Wind Velocity: 81 mph; Shell Weight: 20,506#; Roof Weight...

Part and Inventory Search