  1. BearB

    Electrostatic Strip Oiler HVPS Ground

    I have question about an Electrostatic Strip Oiler (ESO) used to coat oil on a steel continuous strip. The ESO has a High Voltage Power Supply for the top set of oil valves and High Voltage Power Supply (HVPS) for the Bottom set of oil valves. All has been operating OK until about 2 weeks ago...
  2. BearB

    VFD choice for vertical water pump

    I would like to thank this site and all that contribute. I am working with a pump company at our company installing 2 vertical water pumps. The motors will be 100hp, 480v & 150hp, 480v. I have a choice for the VFD's: AB Power Flex 400 or the Eaton Cutler Hammer SVX9000. I have used the AP...
  3. BearB

    VFD choice for vertical water pump

    I would like to thank this site and all that contribute. I am working with a pump company at our company installing 2 vertical water pumps. The motors will be 100hp, 480v & 150hp, 480v. I have a choice for the VFD's: AB Power Flex 400 or the Eaton Cutler Hammer SVX9000. I have used the AP...
  4. BearB

    VFD Fault need ideas

    I have a VFD (AB Power Flex 70) operating a 5 hp motor controlling a progressive cavity pump pumping starch material. The system is set up to pump the material for a time then flush for a time after material is used from tank system cycles again to fill the storage tank. This system has been...
  5. BearB

    Sensor for Sheet Break on Paper Machine

    I have used several types of Sensors to detect Sheet Break on Paper Machines without problems, both reflex and diffuse relective, also thru beam. I am wanting to install a sheet break device near a Coater where coating that gets applied to the paper surface. The Coater currently has a...
  6. BearB

    DC Motor Air Switch question

    I have a 40hp DC Motor on a Digital Drive and I would like alarm maybe with a flashing light, not shutdown if the Motor Blower is not operating. This Drive is stand alone not connected to PLC or DCS. The Motor Thermal Switch is going back to the Drive but I would like to catch the problem...
  7. BearB

    Transformer noise

    I have a Line Tamer CLT 5000 GTW Transformer with 120v in and 120 out feeding a Panel for several instrumentation devices. This unit is rated for 29 amps and is pulling 8 amps when measured, nothing on the load side has changed in over a year. It was noticed making a very loud humming noise...
  8. BearB

    Ground Fault Relay trip on 2300v starter

    Any thoughts or direction on this would be appreciated. The plant where I work we have had a GE 228X275 on a Ground Fault Relay in a 2300v Full Voltage Induction Motor Starter trip when the motor stop switch was pushed, routine way it is stop. This has happen twice, I did not see it I was told...
  9. BearB

    Reading Armature Current with a Clamp On Amp Meter

    I have read Armature Current with a Clamp On Amp Meter many times on AC and DC Motors. However on DC Motors I have generally read a lead to see if it looked normal. Recently I had a 7.5hp DC Motor that seemed hot when I shot it with a Pyro, 167 F. I then checked the Armature leads at the Drive...
  10. BearB

    Flow Switch to detect Seal Water

    I need to install a flow switch to detect Seal Water to interlock the starting of a 2300v motor. Does anyone know of a product that they may have used in a simliar application?
  11. BearB

    Flow Switch to detect Seal Water

    I need to install a flow switch to detect Seal Water to interlock the starting of a 2300v motor. Does anyone know of a product that they may have used in a simliar application?
  12. BearB

    VFD Min speed ?

    I am just starting to use VFD's, I have a learning curve. I have an application where I recently installed a small VFD and 1 HP Inverter Duty Motor on a pump. The pump we had in spares and is used to move liquid. The rate Operations needs it to flow came out to be about 1000cc but to get this...
  13. BearB

    Motor ro VFD

    This will be a simple question for you guys on here. I have a vent fan that is controled by a GE 30HP 480 v Frame 286T motor using a magnetic starter. I was considering slowing the speed of the fan down because too much air is moving in the room. I have a unused Allen Bradley VFD that is rated...
  14. BearB

    AB Power Flex 70 VFD Digital In parameter question

    AB Power Flex 70 VFD Digital In Parameter. 361-366 Parameters are set up for Digital In's with values of 0-46. I am using value 4 "Aux Fault" to sense a motor thermal overload and fault the drive. I have an empty parameter and would like to fault the drive from another device. Does anyone...
  15. BearB

    Watt Transducer Problem

    I am rebuilding a 2400vac Induction Motor Starter. It all seems to work except for the Watt Transducer. I am using 2 CT's and a PT. The Watt Transducer has negative output or low positive when moving CT and PT wires around trying to troubleshoot. The CT's are bar type and bought new without...
  16. BearB

    Full Voltage non Reverse 2300v induction Motor Starter

    Where I am working they want to rebuild a Full Voltage non Reverse 2300v induction Motor Starter. I have not worked much with medium voltage starters and I am asking for assistance. We have several older 2300v Induction motor starters that have had the motors and equipment removed. I am going...