Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: rab1944
  • Content: Threads
  • Order by date
  1. rab1944

    T2a definition in API 650 Variable Design Point

    Would someone please define t2a in API 650 Section 5.6.4.5 (Variable Design Point). Thanks
  2. rab1944

    Top Angle Placement

    What is the preferred method of attaching the top angle to the top of a tank shell, lap welded (Figure F-2 Detail b) or butt welded (Figure F-2 Detail d).
  3. rab1944

    Non Staggered Seams in API 620

    What is the logic in API 620 Section 6.9.2 (11th edition add 1)in allowing plates to not be staggered? Thanks
  4. rab1944

    laminating existing tank shells with new sheet steel

    Is there any restriction on welding a thin gauge less corrosive sheet material over the existing tank shell and bottom. This would be done with lap welds and plug welds. Thanks in advance
  5. rab1944

    NFPA 22 Underbottom protection - Section 5.6.7

    I would like to place an NFPA 22 Fire Water Tank on a ringwall foundation. The tank is about 40' dia. Given the options for protecting the bottom underside, it would seem at first glance that the sand/lime mix with a ph of 6.5 to 7.5 would be the best option. However, finding the proper...
  6. rab1944

    API Agenda Item for API 620 Apx. X

    Can anyone give me the link to API Agenda Item 620-285 Appendix X Revision 4? Much appreciated.
  7. rab1944

    API 650 Add 2 Apx. Y - Correction

    Ok, let me try this again. I meant to ask about API 650 Add 2 Apx. Y
  8. rab1944

    API 659 Add. 2, Apx Y

    Does anyone have any insite to share regarding the new Monogram and Licensing Program discussed in APx Y?
  9. rab1944

    NFPA 22 - Stainless Tanks?

    Does NFPA 22 allow for tanks constructed in stainless steel?
  10. rab1944

    Given mawp as a design parameter rather than internal pressure

    How do I set up Compress when given mawp rather than internal pressure as the design parameter? Thanks
  11. rab1944

    Seismic freeboard and Design Liquid Level

    Must the Seismic freeboard in SUGII and III designs need to be added to the design liquid level. EC.3.1 states that these groups "indirectly influences the performance level expected of the tank." I feel that this is probably not necessary and is already accounted for since E.7.2 speaks of the...
  12. rab1944

    Tank design life

    What resource can give me the process to determine the theoretical design life of an API 650 AST. Thanks for the guidance.
  13. rab1944

    Annular Plate Requirements in Apx. X

    Has anyone noticed that the stress thresholds requiring the use of an annular plate in Apx. X.3.2 are the same as when using carbon steel? That seems odd when the duplex allowables are higher.
  14. rab1944

    Double Wall Tank Annulus Covers

    Is anyone aware of a limitation for the size of double wall tank that can have a roof over the annulus space. This may go into NFPA 30 and I am caught between a customer and an engineer. The enginner says that there is a 20,000 gallon thresshold for tank with a covered annulus. Thanks for...
  15. rab1944

    API 653 allowed thickness different between courses

    I am being asked to replace a 1/2" thick carbon steel course with a 5/16" thick stainless course. The course above the replacement is 1/2" carbon steel. I know you would not do this with a new tank but would this be allowed in API 653 or would section 9.3.3.2 disallow this by the "no more than...
  16. rab1944

    API 650 and Duplex design stresses

    Does anyone's crystal ball indicate how API 650 and 620 will classify Duplex (2101, 2205, etc.). Will it be placed in Apx. S or will it be treated as a carbon steel?
  17. rab1944

    50' dia. double butt welded bottom

    Any suggestions on double butt welding a 50' tank bottom. I had planned to put it on cribbing, but they the bottom shell ring would need to be welded to the supported bottom to weld out the corner weld and make the bottom closing seam to minimize buckling. Are there any better ideas? Thanks...
  18. rab1944

    API 650 F & S Roof Design Stress with the Design Temp. exceeding 250

    Any suggestion for choosing an allowable stress for an API 650 F and S tank with a design temp. in excess of 250 degrees. The umbrella roof needs to be designed per API 620 but it tops out at 250 degrees F. and my design temp. exceed this by over 100 degrees F.
  19. rab1944

    Top and Intermediate Wind Girder Calculation - Sect 5.9.6 and 5.9.7

    Can someone provide the reason for the change in the Z formula from (V/100)^2 to (V/120)^2 in the last part of the formula? The same question applies to the H1 formula where it changed from (100/V)^2 to (120/V)^2. I know this is old news but your comments would be appreciated.