  1. Tinh123

    Extreme Minimum Short Circuit Required for the HVDC cable

    Hi, I'm not too familiar with HVDC cable operating characteristic so any help would be appreciated. I was asked recently to determine the extreme minimum short-circuit required for the operations of the future installed HVDC line. From what I have been reading the last 2 days is that this...
  2. Tinh123

    Short Circuit Testing

    A field person asked me this question and I couldn't find the document to justify, so we need your help. Given a 3-phase transmission line with length (L)and all three phases are shorted, what is the 3-phase voltage need to apply in the other end to achieve an "X" Amp Line-Ground Current for...
  3. Tinh123

    Transformer Impedance Calculation from Test Data

    Hi, I'm trying to determine the appropriate way to represent 3-winding Delta transformer to its equivalent Wye representation. The given data were: Primary : Secondary voltages, its MVA rating, MW loss, and %Z. I saw an old note in the past which indicates the calculated resistance as %R =...
  4. Tinh123

    Phase Angle Regulators

    Hi, I'm trying to solve a loadflow case in PSSE and kept getting the problem of PARS operate outside its constrained boundaries. Need some help with under what condition does a phase angle regulator would fail to operate, and how may I be able to mitigate?
  5. Tinh123

    Blown up Cases in PSSE

    Hi all, Any advices in solving blown up case in PSSE? I have been burdened with a very difficult studied case and can't get it solve. Any strategy would be appreciated. Thanks.
  6. Tinh123

    Reactive Power Absorption by Series Reactors

    Is there an equation which would explain the reactive power absorption of a series reactor with impedance X. Assume that the series reactor between point 1 and point 2. Thanks for any help.
  7. Tinh123

    Reactive Power Flow

    Is there an equation for reactive power flow? (I know for real power movement the equation is EVsin(E-V)/X, But couldn't find anything for reactive movement)
  8. Tinh123

    Fault Current Contribution - HV transmission

    Thanks Dandel, davidbeach, and others who gave me very beneficial suggestions. I have recently worked on a problem of fault current contribution from the surrounding elements on a high voltage bus 138 kV. What I noticed is that when i changed one set of generation and transformer using...
  9. Tinh123

    Transformer in-rush current at distribution level

    I'm currently investigate the effect of transformer in-rush current at a distribution level. Need to know what instigate this behavior and its effect on the system. If you know any source/websites for which I could study about this phenomenon, it would be very helpful. Thanks, and have a...
  10. Tinh123

    Convert Transformer Impedances to different voltage level

    Hi, I'm very new at this and need your advises. I was recently asked to determine the fault current contribution of a group of generators locates at a bus within our system. This group of generators was represented as a single equivalent source in Aspen software and connected to a 345 kV...