  1. davster01

    Averaging temperature sensors for two mode of heating

    I am designing a approx. 20000 sq. ft. building that will be served by 8 roof top units (RTUs) in ASHRAE climate Zone 6. The RTUs have not been selected yet. Let us look at one RTU. This typical roof top unit might serve 4 closed offices, and 2 boardrooms. In the shoulder seasons (Spring...
  2. davster01

    HAP v4.22 Model Question Inner Courtyard

    Hi, I am designing a new 20 000 sq. ft single storey building with different roof slopes and an inner courtyard. We are going to use multiple roof-top units. Nothing too complicated from a load calc. point of view. For this reason, I want to use this project to use HAP for the first time. I...
  3. davster01

    Maximum 90 deg bends before inlet suction guide

    Hi, I am currently working on my first chilled water plant design. For the condenser water circuit we are intending to use base-mounted centrifugal pumps. We are considering using suction guide on our pumps. I know that a centrifugal pump needs approx. 5 diameters of piping before pump inlet...
  4. davster01

    At what size do emergency / service generators require pre-lube pumps

    Hi, I would like to know what is the threshold value at which the service and emergency generators typically have a pre-lube pumps. By the way, I am typically involved with land-based units under 60 kW. We do not have such pre-lube pumps. Thank you
  5. davster01

    AISI 1018 vs. AISI 1022

    Hi, We have asked to have some pins fabricated using AISI 1018 steel. The machine shop is asking us if they can use AISI 1022 instead. I know the mechanical properties are actually better but more brittle due to slightly higher carbon content. But is there a chance of galvanic corrosion if...
  6. davster01

    Leak Detection of Petroleum Double-Wall Tank

    Hi, There seems to be many methods of continuously monitoring an aboveground double-wall tanks for leaks. We were thinking of using a Veeder-Root TLS 350 for both piping and the tanks. These are a couple of 10 000 liters tanks feeding a power generator that is running continuously. The...
  7. davster01

    Flight Deck Fire Suppression Guidelines

    Hi, I was asked to research Codes, Regulations and Guidelines that are dealing with Flight Deck and Helicopter Hangar Fire Protection requirements. We have an old Transport Canada standard and there is also a IMO Resolution A.855 (20). But there is very little direction provided by these...
  8. davster01

    Engine re-tuning requirements for biodiesel

    Hi, So far, all the studies looking at the emissions improvements of biodiesel over petrodiesel seem to be skewed in that they do not consider the potential need to re-tune engine timing to account for different cetane number of these respective fuels. Have the members of this Community ever...
  9. davster01

    Options for small diameter Aboveground Double Wall Piping

    Hi, I work for the Canadian Government. Recently the Storage Tank Systems for Petroleum Products and Allied Petroleum Products Regulations were enacted. One of the requirements is to have a secondary containment system for both the tank and piping. While for the tank part it is easy, it is...
  10. davster01

    Pumps, Environmental codes and regulations

    Hello all, Recently the agencie I work for had to remediate a site due to diesel oil spillage. This spillage was due to the cracking of a diaphragm of a positive disp. pump. The pump was located on an unmanned remote site. Is there any guidelines, codes or regulations available out there...