Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: knelli
  • Content: Threads
  • Order by date
  1. knelli

    Calculator bit the dust.....

    Hi all, I am on my third TI-85 and the display is failing :(. I looked at other TI models including the TI-83, TI-84 Plus C SE and TI-89 Titanium. I was able to emulate those models on my phone to see if I'd like them. I still prefer the TI-85, and really want something that does conversions...
  2. knelli

    Vented steel form deck

    I am spec'ing a steel form deck. Do you know when it would be appropriate to use a vented deck (type CSV) versus non vented (type C)?
  3. knelli

    "Project Engineer" Title

    Hi, I am a licensed professional engineer (structural) that works for a Design Build firm. Our company managers have a habit of calling new project managers "Project Engineers". I have a problem with this, because the people they are titling as "Project Engineers" are new out of school with...
  4. knelli

    Joist bottom chord out of plane bowing

    Hi all, I received an email today from a jobsite asking what the tolerances are for a joist bottom chord to be bowed 1" to 2" out of plane compared to the top chord. The bridging has already been installed. Has anyone else ever run into this? I would assume a joist is not designed to...
  5. knelli

    Weld Nomenclature

    Hi, When calling out an intermittent weld, say 4"@12", does that mean there is 12" of space between 4" welds or are the welds @ 12" o.c.? Blogett's book notes that the 12" is the "distance between centers" which I would think means the 4" weld is 12" o.c. I have a set of drawings that calls...
  6. knelli

    Crane Beam Design

    Hi, Does anyone have experience with this AISC crane beam design spreadsheet? It will not let me select a W shape plus Channel. Any idea why? Thank you, -K
  7. knelli

    Special Reinforced Masonry Shear Wall

    Hi, If you have a building in Seismic Design Category D, Special Reinforced Masonry Shear walls are required. Per ACI 530, "1.13.2.2.5 c)Shear reinforcement shall be anchored around vertical reinforcing with a standard hook." This makes me think that horizontal reinforcing needs to be via...
  8. knelli

    Stoops in the south

    Hi, In the north we design all of our exterior doors with stoops that have frostwalls and footings that extend 4'-0" below grade. We are preparing a design build proposal for a building in Oklahoma. How are stoops typically designed/built there? I am told that the frost depth is about 22" in...
  9. knelli

    Slope roof perpendicular to joist span

    Hi, We are designing a big box store with outdoor storage. The prototype drawings show the joists spanning perpendicular to the roof slope so that the roof deck ribs can be used for drainage to a gutter. The project manager wants to increase the slope of the roof, I'm suggesting 1/2" per ft...
  10. knelli

    Review of ASCE PEMB course

    Hi, Has anyone taken the ASCE course "Design and Strengthening of Shallow Foundations for Conventional and Pre-Engineered Buildings" What were your thoughts on the course? Was it worth the traveling and expense? Thanks -K
  11. knelli

    Sloped Steel Joist Design - Allowable Girder Deflection

    Hi all, Here we go again with the sloped member discussion with a new twist. I read the threads related to this topic (see referenced threads below) Background Information: I am involved in designing some buildings for the federal government. Unfortunately they like roofs with 3/12 slope...
  12. knelli

    DH Series Joist

    Hi all, We are modifying a building that was constructed around 1972. Fortunately we have existing drawings. Unfortunately, following joists are specified: -28DH9 with 3 1/2" bearing shoe, 50' span -18DH8 with 3 1/2" bearing shoe, ~30' span Also specified are: -18H6 with 3 1/2" bearing...
  13. knelli

    Dampening mechanical vibrations

    Hi, I have been asked to design a slab on grade to dampen the vibrations of a 150 hp dynamic load. The senior strucutral engineer here says that he usually makes sure the slab below and about 2'-0" around the piece of equipment weighs twice as much as the piece of equipment that is vibrating...
  14. knelli

    Perforated Shear Wall Design

    Hello, I have "Design of Wood Structures, ASD" 4th edition published in 1999. The book outlines perforated shear wall design for wood framed shear walls. Basically, the shear wall capacity is calculated by adjusting shear capacity of the entire wall by a factor that is calculated by comparing...

Part and Inventory Search