This is a waste of time to me but I have to resolve this question forced upon me by a Contractor's interpretation of ACI 318.
This concerns 46 inch square "pedastals" for a six legged water tank structure.
My interpretation: Use ACI 318 -10.8.4 and 10.9.1 for compression members and...
need a guide performance spec for fall arrest system for use in aircraft hangars. Replacing old iinsufficient 1/4" cable and brackets. Any suggestions where to look/go helpful vendors??
Is there a guide or info available for truck parking areas? Is there info avaialble about delayed use of parking area until pavement "sets"?? Anything I can do/use in the pavement design to keep trailer jacks from sinking (other than using concrete or steel plates)???
Is there an ASTM or AWS spec for proper dye testing of 12 ga stainless sheet fusion welds? We're field assembling a continuous water tight gutter trough for a swimming pool.
I don't have any AWS codes other than 1.1. I believe 1.6 is for stainless. Thanks.
Need to find the tensile capacity of a bolt in a tapped hole condition.
Lifting a tank that has 6-3/8" tapped holes about 3/8" deep. Tank flange is Cu-Ni and weighs about 5,000 lbs. Considering FS of 2 on lift and additional 20% for prying action on bolt heads. Therefore I need a...
Is there any special wind load provisions necessary at airport facility structures due to jetwash or rotor wash from helicopters? I haven't seen or found anything. Any military specs maybe??
We've been seeing more precast box structures for small wastewater plant applications. Most are two or three piece stacked similar to manholes. Concern is very thin walls for buried application (2 3/4" is the smallest!) and wire mesh reinforcing. Design is by yield line analysis for two...
Looking at a 10 year old clearwell that has been exposed to an aggressive water with a Langlier Index of -1.3, Alk of 76 (mg/l as CaCO3), Hardness of 160(mg/l as CaCO3), and CO2 of about 50 mg/l. After 10 years the cement paste has been "dissolved" to about 1/4" in depth and only...
Looking at a 10 year old clearwell that has been exposed to an aggressive water with a Langlier Index of -1.3, Alk of 76 (mg/l as CaCO3), Hardness of 160(mg/l as CaCO3), and CO2 of about 50 mg/l. After 10 years the cement paste has been "dissolved" to about 1/4" in depth and only...