  1. JoeWill123

    Sprinkler riser size

    Why would an A&E desighn a sprinkler riser in such a way that the existing water main to tape into is 6 inch, but the A&E is desighning an 8 inch on top of the 6 inch pipe as it enters the facility ? Is it normal to go from a 6 inch supply line to a 8 inch riser? If so why? Joe G. Willett...
  2. JoeWill123

    NFPA 72- Fire Alarm question...

    Does anyone know any further wording in NFPA that talks about any fire protection equipment, device, system, ect...that if installed (no matter when) it must be 100% operational or removed if not needed or required? The only thing I am coming up with is NFPA 72, paragraph 4.3.1. Does...
  3. JoeWill123

    VISTA

    Is the new windows VISTA worth it ? compared to windows XP ? Joe G. Willett Jacksonville, AR
  4. JoeWill123

    Sprinkler Supply line

    What NFPA standard tells me if the fire main must be 6 inch or 4 inch to for the purpose of a new suppression system in a facility? How do I know if a 4 inch is permissible? VS. the 6 inch Joe G. Willett Jacksonville, AR
  5. JoeWill123

    Medical (Dental office) Oxygen use

    What is the cubic foot size of "H" type oxygen cylinder? There seem to be a lot of requirements for storage/use of these cylinders after 300 cubic feet size bottles. Joe G. Willett Jacksonville, AR
  6. JoeWill123

    Clean fire fighting agents

    IAW NFPA, what are some clean fire fighting agents? I am aware of Halon 1301, 1211, and CO2...what else does NFPA endorse? Joe G. Willett Jacksonville, AR
  7. JoeWill123

    Suppression System pump

    Must all electric suppression system pumps have a back up generator? Joe G. Willett Jacksonville, AR
  8. JoeWill123

    HI-Expansion Foam

    Is there any limit to the size (square footage of floor space) that na aircraft hangar can be for using hi-expansion foam? Joe G. Willett Jacksonville, AR
  9. JoeWill123

    Hi-Expansion Foam Aircraft Hangar

    Is there any maximum size to the aircraft hanagr for effectively using hi-expansion foam?
  10. JoeWill123

    Mimimum sq ft for not having suppression

    Is there a minimum sq ft reg for not having to install suppression? like less than 200 sg ft ? I read the bathroom and closet stuff. But what about just another small room ?
  11. JoeWill123

    Abbrassive rooms protection

    Does an abbrassive blasting room require suppression protection?
  12. JoeWill123

    NFPA 101, paragraph 24.3.5.1

    Is anyone really putting sprinklers in new houses? As per, NFPA 101, paragraph 24.3.5.1 The building boom around my area is going like crazy and not one those houses have a sprinkler in it.
  13. JoeWill123

    Air Craft Hangars Suppression Systems

    Has anyone done any work with converting Aircraft hangar suppression 3% AFFF systems to Hi-Ex foam systems? If so, any huge issues? problems?
  14. JoeWill123

    FM-200

    Is FM-200 approved for use at USAF (Air Forec) facilities? What is the reference?