Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: brokenpile
  • Content: Threads
  • Order by date
  1. brokenpile

    Shear Studs and Deck Pans

    We have a steel tube truss bridge 14' wide by 130' long that has floor beams 7'-2" o.c.Bridge had to be galvanized and painted so the nelson studs where installed before galvanizing 1' o.c. across the floor beams.Bridge company sent out 2" non composite 20 gauge deck pans which we flame cut...
  2. brokenpile

    Steel Bridge Truss

    I have a plan showing a pedestrian steel truss bridge showing a bottom chord of 8"x 8" steel tube.Specifications read "The steel truss shall be designed to include a redundant bottom chord comprised of double channels" Can anyone tell me whats that means since the drawing doesn't depict what the...
  3. brokenpile

    Under Deck Platform

    We have a steel frame deck 80 feet above the ground. The W 30 beams are five foot on center and before we put the steel deck down and pour the floor we have to install all the piping on the underside of the beams.Can't use a lift underneath the deck due to the extreme slope so we have to hang...
  4. brokenpile

    anchor block wall , mirafi 2XT

    Geogrid lenght for a Anchor Concrete Block wall ,is 60% of the height of the wall safe enough? Placing it on every other course 16" oc.max height 11 feet
  5. brokenpile

    Driving sheet pile

    We are driving PZC 13 sheets with vibro hammer in the Newark Bay along the Bayonne shore line.Owners enginner specified a 25 foot long sheet.Then we have to drill grouted 2" hollow bar tie backs at 30 degrees ,60 ft long.As we drive the sheets the others that are set to grade are sinking several...
  6. brokenpile

    Grouted Tieback Anchors

    We bid a projet for installing 25' long PZC 13 steel sheet piling with grouted hollow bar anchors 2".Bulkhead application with 12' exposed to the bay.Design Engineer plans show detail drawings as such and he noted the anchors to be 12' on center maxium with a waler.Wall design for 7000 psi per...
  7. brokenpile

    Precast concrete panels in saltwater

    We have a lagoon with 700' of 9' high existing concrete bulkhead which is old and spalding in areas.Owner wants us to drill in dowels and attach 6"x6" wire and pour a new 8" face in front of old wall.To avoid pouring concrete in saltwater tides we want to use a 6" thick precast wall panel and...

Part and Inventory Search