  1. castle74

    Normalized A572 Gr 50?

    As anyone dealt with normalized A572 50, I was under the impression that it is only supplied in the as-rolled condition.
  2. castle74

    ANSI 1026 EQUIVALENT

    I know this is an easy one for you gentleman; could ASTM A105 be used as a replacement for ANSI 1026. The 1026 material (normalized forging)is on an 18 week backlog, engineering wants to see if A105 would make a good replacement. The forging requires yield and CVN restrictions (nothing high)...
  3. castle74

    QW-163

    In ASME IX, QW-163, does that interpret as one single discontinuity exceeding 1/8", and not a collection of discontinuities (say five 1/16" discont.)exceeding 1/8". So in other words,the bend specimen can have many discontinuities as long as no single one exceeds 1/8".
  4. castle74

    QW-407.2

    Gentleman, I had submmited a PQR & WPS to a 3rd party surveyor for review; these were in accordance with ASME IX. The PWHT time on the PQR is 2.5 hrs. at 1150 F, I had stated on the WPS that the minimum and maximum time at temperature allowed would be 2 to 2.5 hrs.(my interpertation of QW-407.2)...