On a ss304H Sect.8, Div.1 pressure vessel with a design temperature of 1380 F, and max. operating temperature of 1310 F there is a class 600 flange subjected to high external nozzle loads. Per my Compress program if the loads were imposed on the flange, the flange would need to be a class 1500...