  1. friend81

    Advantages of Closed Slot Stamping vs Open Slot Stamping

    Hi Guys, Recently i came across an information that some manufacturers of Submersible Motors use Closed slot Stamping design in Higher kW ranges over the conventional Open slot stampings. The disadvantage of a closed slot stamping will be the delay in production as it may take upto couple of...
  2. friend81

    250HP Induction Motor - Greater Phase to Phase current Imbalance

    Hi Folks, Hope someone can help me on the below issue, We have installed a 250HP, 380V, 60Hz Submersible pumset at 340m deep in a Borewell . The motor is a 6 lead motor & all the 6 leads were taken out of the well & connected in DELTA as a 3 wire motor before conencting to the VFD. After...
  3. friend81

    Auto_transformer rating

    Hi Guys, I would like to to know if the calculation for dimensioning a 3 Phase Auto-transformer is same as that of a power transformer ie (Volts x Amps X 1.73)/1000 ? i am thinking of installing a 30HP,380V pump set in 220V,3Phase,AC power supply by employing a step-up auto-transformer, so...
  4. friend81

    Advantages of 12 lead 460V,60Hz WYE-DELTA Motor over 6 lead 460V motor

    What is the advantage of having a 12 lead 460V,60Hz WYE-DELTA Motor over 6 lead 460V WYE-DELTA motor ? The motor is for deepwell application & mechanical type reduced voltage starter is used in both the cases.
  5. friend81

    Submersible Pumpset Thrust Bearing Vs Check Vave

    We have a 60HP, 440V, 60Hz Submersible Pumpset installed in a borewell at 210m depth. The delivery pipe is of 6" diameter & after 15 days of operation the current of the pumping unit surged to 156A from its 95A. After dismantling the motor we found that the thrust bearing of the motor is...
  6. friend81

    Calculating SFA

    I tried to figure out the SFA of a motor using the following formula, SFA = SF*HP/[SQRT(3)*Vll*EFF*PF] Whereas, SFA = Service factor Amps SF = Service factor SQRT(3)= 1.732 VII = line voltage EFF = Efficiency PF = Power Fator Considering SFA = 1.15*5HP / (1.732*220*0.75*0.81) = 5.75...
  7. friend81

    cable selection

    Dear Experts i have a 5HP, 220V, 60Hz 4ïnch submersible motor whose max.current(SFA) is 19.5A. It´s coupled to a borehole submersible pump and installed at 350m with a supply cable (copper)of 10mm^2. But the actual current consumed by the motor is 23A. When contacted the supplier they informed...
  8. friend81

    Start Capacitor ratings

    I have a single phase 3HP 230V 60Hz capacitor start capacitor run submersible motor which came with a 250/300mfd, 230V rating start capacitor & 36+36mfd, 440V rating run capacitors. As this start capacitor is defective i need to replace it but the rating of the start capacitor comercially...
  9. friend81

    Over hanging portion

    Is there any relation between the overhanging portion(length) & efficiency or life cycle of a motor. For example an motor with a less overhanging portion will be having a better efficiency than the one with a large overhanging portion?.
  10. friend81

    Pump performance as per ISO 9906 Anex A & 2A

    Helo friends throw me some light I would like to know the acceptable tolerance levels in centrifugal pump performance as per ISO 9906 Anex 2A when compared to ISO 9906 Anex A. Any kind of help is highly appreciated.
  11. friend81

    Friction loss

    Dear Friends, I would like to get a clarification in calculating friction loss in a PVC pipe of 100m length.Using the formula hfs = 4f L/D x V*2/2 X g, Q = 30cub.m/h L = 100m D = 51.4mm (ID of UPVC pipe) Kin.Viscosity of Water @ 30deg.C = 0.801 cSt Results i got are as follows V =...
  12. friend81

    helo friends

    Helo friends throw me some light I would like to know the acceptable tolerance levels in centrifugal pump performance as per ISO 9906 Anex 2A when compared to ISO 9906 Anex A.
  13. friend81

    PH resistance of SS316 material

    I am curious about what will be the PH handling capacity of SS316 material. When pumps are made with SS304 manufacturers are recommending for a PH of 6.5 to 8.5. Hence what will be the PH range for SS316 material.
  14. friend81

    .avi & .rar extension files

    hai friends! i would like to know how to play/open .avi & .rar extension files. i have few video files with me but i couldnt able to open it.
  15. friend81

    Like to know

    Hi friends Can anyone of u please tell me what will be the class of Insulation of Water filled rewindable submersible motors (Winding is made of water proof insulated copper wire). Normally manufacturers claim it as Y class? But i have never seen anywhere the temperature ratings for Y class...
  16. friend81

    Service Factor

    Hi Friends! i am new to this Eng.Forum. I am working with a company manufacturing submersible pumps & i would like to know what is the difference in the electrical design between a motor with Service Factor & without Service factor, and also mostly service factor is declared for 60Hz motors &...