Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: Deutero
  • Content: Threads
  • Order by date
  1. Deutero

    Welding Pre-1920 Steel to New Steel

    I am asking this question for PT999 as well as myself. PT999 has posed a similar question at thread507-167093. Can an existing 15" wide flange erected in 1907 be field welded to a new A992-Gr 50 wide flange? What material would the 1907 beam be composed of? Thank you ...
  2. Deutero

    The Birth of Nominal Wood Sizes

    When was the birth of nominal wood sizes? What is the origin of nominal wood sizes? Just curious ...
  3. Deutero

    1907 Lumber Design Values

    Actual 3x12 floor joists at 16" oc for the second floor of a former firehouse wanting to turn restaurant and banquet hall. Where can I find design values and a reasonable assumption of species for this structure built in Door County, Wisconsin in the year 1907? Keeping in mind, the lumber is...
  4. Deutero

    1907 Lumber Design Values

    Actual 3x12 floor joists at 16" oc for the second floor of a former firehouse wanting to turn restaurant and banquet hall. Where can I find design values and a reasonable assumption of species for this structure built in Door County, Wisconsin in the year 1907? Keeping in mind, the lumber is...
  5. Deutero

    Required Number of Anchors & Mechanical Anchoring

    I recall approximately ten years ago, when a PEMB company (specifically ABC) had changed their rigid frame base plate anchoring from two anchor bolts to four anchor bolts. Apparently for some time, the two were acceptable. I do not recall whether the change was a code requirement or revised...
  6. Deutero

    Mech / Equip / Display Mezz Live Loads

    IBC does not list minimum live loads for mechanical, equipment or display mezzanines. IBC 1606.2 states to include fixed service equipment dead loads. After equipment loads have been considered, what do you use for overall live loads, for the above specified commercial occupancies? Thank you ...
  7. Deutero

    Sill Anchors

    Is there was a requirement, in IBC, stating that when fastening preservative treated wood sills to concrete foundation, the anchors must be of corrosion-resistant material such as galvanizing or stainless? I thought there was and I cannot find it. Thank you...
  8. Deutero

    Gypsum Shear Walls

    RE: IBC 2306.4.5 I know I've used this table in the past, and I thought that the table represented gypsum used on only one side of wall. Therefore sheathing both sides allows me to double the values. But, I'm not reading this anywhere. Also, there does not seem to be any reduction factors...
  9. Deutero

    Ladders Rungs - Fixed or Pinned?

    3/4" dia ladders rungs, 3/16 fillet welded all around, each end, to flat bar 3/8 x 3 stringers. The rungs do not penetrate the stringers. Are the supports a fixed or pinned connection? Thank you ...
  10. Deutero

    Masonry Lintels

    In a masonry lintel requiring two or more couses, the bottom course will be composed of bond beam units with horizontal rebar. What about the required courses on top of that? Should they also be bond beam units, common cored units or either, depending on the application? Thank you ...
  11. Deutero

    Section Modulus "Se" in Metal Deck

    I've seen Sx, Sy, Sn, Sp. What is "Se" referring to? I am seeing it in a Section Properties table by McElroy Metal Deck. Thank you...
  12. Deutero

    American Standard Channels - AISC 9th

    I am preparing some miscellaneous steel shop drawing details. I want to have a gusset connector plate shop welded to a C12x20.7. AISC 9th gives the average flange thickness, grip and "k" dimension. but what is the actual thickness at the extreme toe end/edge of the flange? Thank you ...
  13. Deutero

    CFS Joist Bearing

    3/4" 48/24 floor sheathing over 1.0C20 metal deck over CFS floor joists bearing on CFS wall. If the joists are (Simpson) tension cross-braced at mid-span, not suseptible to web-crippling and metal deck is fastened to cfs joists and rim track at 12" oc, is there a need to have the joists...
  14. Deutero

    CFS Deck

    Other than Vulcraft, please direct me to section properties for floor and roof deck that may be published either by AISI, SDI or other reputable inst's, org's, assn's, etc... Thank you ...
  15. Deutero

    "B" Roof Deck vs "C" Floor Deck - For Floor Use

    I've specified "B" deck for roof applications. Throughout the years, for FLOOR applications, I've seen B-deck specified on various plans from other engineering firms and have had it requested by contractors, due to in-stock convenience I presume. Therefore, not seeing any "red-flags", I also...
  16. Deutero

    NDS Side Member Thickness

    RE: 2001 NDS TABLE 11J Does "Side Member Thickness" refer to the thickness of the member being supported by the Main Member? Thank you ...
  17. Deutero

    Welding 12 Ga Material

    Fabricating a rectangular frame with light gage structural C-Sections, 45 degree mitered at corners. AISC 9th TABLE J2.4 lists a minimum fillet for up "To 1/4 inclusive". Is an 1/8" all-around weld to much for 12 ga material? Thank you ...
  18. Deutero

    Shear Capacity Adjustment Factors

    Through interpolation, can IBC Table 2305.3.7.2 be used for wall heights other than the 8 and 10 foot heights listed? Thank you ...
  19. Deutero

    Shear Wall Anchoring

    RE: NDS I've often wondered why there is not a value for shear perpendicular to wood. The tension of the overturning forces of a shear wall, that would be resisted at the sill anchor certainly will cause stress at the sill plate cross section. What kind of force is applied to the sill plate...

Part and Inventory Search