Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: Abiodun1
  • Content: Threads
  • Order by date
  1. Abiodun1

    Positioning PCV on pump discharge line

    Hi, I need information how to set and represent the control logic for positioning of Pressure Control Valve in pump discharge line on P&ID. The pump is pumping a seawater to be processed for well injection. The pump discharge line is an 8" line discharging into a commom header of 20" line in...
  2. Abiodun1

    Relationship between irregular shape and stardard oriifice size.

    Hi, I need information on how to generate the relationship between irregular shape to standard orifice size. I want to use in calculating the flow of fluid through the orifice. I would appreciate urgent responce. Thanks
  3. Abiodun1

    Load Sharing in compressor

    Hi, I have been studying on the design of a centrifugal compressor. I need information on the control aspects such as the: 1) Capacity control 2) Anti-surge control {am studying that at present) 3) Load sharing (How do one share the load on compressor?) In depth understanding to the above...
  4. Abiodun1

    Sewage Treatment Plant

    Hi All, i want to design a sewage treatment plant. The waste is non-toxic water. The following information was given: Volume: 180 m3/day Diatance between the outlet and discharge point is 500m. please, i need information on how to achieve this task. Thanks
  5. Abiodun1

    Sizing 2-phase Horizontal Vessel

    Hi guys, I want to size an horizontal Surge Vessel to handle 50,000 bopd. The % height of the LSL, LAL, LAH, LSH has been given. There respective respective retention times required has been given. How can i determine the diameter and length of the vessel? I try using DEP but bit confuse...
  6. Abiodun1

    Convergence Of Regenerator Column

    Hi, i am developing a conceptual model for gas dehydration using TEG using HYSYS. The regenerator column for the TEG does not converge. I specify the required information by the column, putting the solver into adaptive mode to enhance convergence, and both condenser& reboiler pressure. The...
  7. Abiodun1

    Heat exchanger design using HYSYS

    Hi guys, how do i use HYSYS to specify a heat exchanger to increase the temperature of a process gas to desired temperature. What is the effect of pressure drop in the hot stream. Regards
  8. Abiodun1

    Vessel Capacity check & Equiment Sizing

    Hi Guys, Can you please tell me how to use HYSYS to carry out the following: vessel capacity check on seperator and scrubber,equipment sizing and nozzle sizing. Thanks
  9. Abiodun1

    pig system design

    what design considerations should be considered during pig trap system design?