  1. mutimuti

    World's Largest Power Transformer

    Can anyone tell me what is the MVA of the world's largest transformer, how many tons with oil and who makes it?
  2. mutimuti

    The question of Infeed : Zonal Protection

    The book (Horrowitz) says even if an infeed exists, we can ignore it for the purpose of Setting Zone one, but must consider it for Zone 2 & 3. Why? Whats the latest trend?
  3. mutimuti

    Protection Coordination of Ring Circuits

    How is it really done? It seems you have bi-directional relays at the source bussbar and uni-directional relays at all the other busses looking towards the source. You then have two sets of uni-directional relays looking in opposite directions. When setting do you consider the situation as...
  4. mutimuti

    Current Transformer Limits

    Can a 150:5 CT survive a 25-30kA fault current?
  5. mutimuti

    Protection Guidelines

    I am looking for guidelines for protecting distribution systtem networks, especially between 11kV (possibly lower) and 66kV. In particular explicit information on when to use fuses or a combination of fuse and circuit breaker. Thank you.
  6. mutimuti

    Picking 0.3333333333 of fault current

    Can anyone tell me the industry standard for protecting radial networks. Some publications for example base the "pick up" on a fraction of minimum fault current, typically 1/3 and the time dial settings based on maximum fault current. Still others use peak load current for pick up and fault...
  7. mutimuti

    My first plc program

    I have connected everything to just switch one light. I have programmed it. I am using Moeller PS4-141-MM1, PLC. When I try to transfer the program, there is a complaint about an already existing program (the last programme was for a different task). There is also a complaint about the...
  8. mutimuti

    Load Flow in per unit: Putting Matter to rest

    I just thought of a new on Per Unit Power System Analysis thread to finalise a previous discussion hoping also that other academics can benefit from my experience. I have just finished doing the simulation of a system example by Stagg & Ei-Abiad,shown in his "Computer Methods in Power Systems"...
  9. mutimuti

    Load Flow for in per unit

    I am an educator and find that many examples for load flow given in textbooks are in per unit. The software which I use uses physical data (ohms, km MW KV etc)and there is no option in my software for this. I tried to use 1kV, 1Km (impedance is given per km) and 1 MVA so that I would not have...