Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: cdi12
  • Content: Threads
  • Order by date
  1. cdi12

    Design Beam For Fall Arrest Anchorage

    In this thread thread507-84756 "SlideRuleEra" suggested that we compare the failure load of harness parts (5,000 lb) to one measure of the failure load of the steel member (the load at 36 ksi yield strength) and "haggis" came up with C4x5.4 spanning 9 ft. Is this correct approach? For 9 ft span...
  2. cdi12

    Seismic Force-Resisting System?

    I am doing ASCE 7-05 seismic calculations of cooling tower support steel structure (see attachment) and I am not sure what seismic force-resisting system it is. Ordinary steel concentrically braced frame (R=3.25) or Special steel concentrically braced frame (R=6) or Steel system not specifically...
  3. cdi12

    Quartz Circular Plate

    Our mechanical engineer is asking me to check circular plate made of quartz. Plate is about 14” dia and 2” thick with a lot (about 150) holes 3/16” dia. All quartz properties (E, yield, allowable tensile stress, …) were given. I am considering modeling this plate with triangular plate elements...
  4. cdi12

    Different Bolt Sizes at Each End of Vertical Brace

    Is it acceptable to use different bolt sizes at each end of vertical brace (3/4” dia bolts at one end and 1” dia bolts at other end)? Thanks, IV
  5. cdi12

    ASME BTH-1 Allowable Stresses

    I am checking something I do not have ASME BTH-1 with me - are all allowable stresses Fy/3 even allowable bearing stress? Thanks, IV
  6. cdi12

    MWFRS or C&C

    Should wind load on purlins HSS10x4 welded to main roof trusses (see attachment) be calculated using factors for MWFRS or C&C? I thought for purlins, in this case since they are part of main wind force resisting system, should MWFRS factors used. In what part of ASCE 7 is this? Thanks IV
  7. cdi12

    0.6D+W Load Comb and 1.0 Factor of Safety

    I have designed canopy spread footing using load combination 0.6D+W and 1.0 factor of safety for overturning and uplift but reviewer wants me to use FOS=1.5 It looks very conservative to me and I could not find this in IBC. However PIP STC01015 Structural Design Criteria Section 4.3.7.2 is very...
  8. cdi12

    Anchor Bolt Design ASD vs. LRFD

    Catalogs for adhesive or mechanical anchor bolts usually give allowable and ultimate loads and their ratio is around 1:4. However ratio between nominal loads (using allowable stress design) and factored loads (using strength design) is less than 1:2. This means allowable stress design gives you...
  9. cdi12

    Wall Design Thickness 9th vs. 13th Manual

    I have just noticed difference in wall design thicknesses (as well as section properties) for Pipes and Tubes between 9th and 13th Manual. Anybody knows why? Thanks
  10. cdi12

    Pretension Load for Guy Wire Supported Flare Stack

    Any guidelines/formulas/references how to calculate pretension load for guy wire supported flare stack. Is it percentage of the cable breaking strength? Thank you very much.
  11. cdi12

    P.E. or PE

    What is “correct” way to abbreviate Professional Engineer P.E. or PE Thanks
  12. cdi12

    Concrete Pedestal Min. Reinf

    What's min. reinf for short concrete pedestals? Some engineers use from 0.5% to 1.0%. Thanks. IV
  13. cdi12

    Spread Footing Design

    Here is a link for example of eccentrically loaded spread footing with two design approaches I have seen and I am just wandering which one is correct. http://www.mooload.com/new/file.php?file=files/211106/1164137438/Spread+Footing.pdf Thanks, IV
  14. cdi12

    Insulated Concrete Form (ICF)

    Anybody used Insulated Concrete Form (ICF) for 4-5 story condos and wants to share design/construction experiences would be greatly appreciated. Thanks, IV
  15. cdi12

    Concrete Mat Expansion Joint

    For 50ft x 25ft x 18in thick concrete mat with 5ft height x 10in thick wall all around (tank spill containment area) is expansion joint required? Thanks,
  16. cdi12

    Eccentrically Loaded Single Angles

    Table 4-12 (AISC Manual 13th) shows available axial strength for eccentrically loaded single angles. For example: L4x4x1/4, Grade 36, KL=5ft, Pmax=13.4kips while Table from Eng. Journal, Second Quarter 1991 (by Wayne Walker) shows Pmax=9.6 kips Anybody knows why? Thanks,
  17. cdi12

    ASCE 7-05 Figure 6-18B

    ASCE 7-05, Page 67, Figure 8-18B (Net Pressure Coefficient, CN for Pitched Free Roofs) shows Load Case A & B. What are these cases? Thanks,
  18. cdi12

    Rectangular Plate Under Concentrated Load

    I am looking for bending moment tables for edge-supported (all possible boundary conditions/combinations - free edge, simple supported of fixed edge) rectangular plate under concentrated load (or distributed load under small tributary area) at any point of the plate. Roark’s book has only...
  19. cdi12

    Foundation Engineering Handbook

    I have received a special offer ($120.00 and free S&H) from McGraw-Hill for Foundation Engineering Handbook (Design and Construction with 2006 IBC) by Robert W. Day. I'll be very grateful for any comments from anyone who bought and used it. Regards, Cdi12
  20. cdi12

    RAM Advanse

    I am planning to buy a structural analysis package and I am considering RAM Advanse. Comments from current experienced users would be appreciated. IV

Part and Inventory Search