  1. kedpe

    Can replace 57 with 4 and not compact?

    I have a contractor asking if he can place a sanitary sewer, backfill w/ 57 stone to a foot over the pipe, then backfill the rest with 4-saying he wouldn't need to compact this. It is in a future parking lot (1-2 years out). Does anyone have experience in this area?
  2. kedpe

    Contraction joint-mesh and dowel placement

    I have a contraction joint detail with 18" dowel bar (in basket) centered about a T/4 deep sawed joint. The welded wire fabric is shown ending 12" from each side of the joint. This produces a 3" gap with no reinforcing, since the dowel bar is only 9" on either side of the joint. Should the...
  3. kedpe

    Utility Trench repair

    One of my clients has asked for a detail that shows trench repair with concrete reinforced with #10 mesh with 6"x6" openings tied into the existing concrete by dowels. Any thoughts or sources on this?
  4. kedpe

    Is there a PIV that is flush with the ground?

    I've rerouted an existing fire loop around a new building on a manufacturing plant site. The owner wants a PIV at every valve location. These are surrounded by 4 bollards. The 2 valves I need to make the connection to existing fire main are in very awkward locations to have an above ground...
  5. kedpe

    sanitary sewer services-

    Why are manhole connections not allowed (discouraged) for sanitary sewer services? A standard drawing for a lateral connection shows a "trench dam" at 10' from the connection. What does a trench dam do, and is it used when the connection is to a manhole?
  6. kedpe

    Pond outlet culvert-HW & anti-seep collar question

    I want to use a 12" pipe to outlet a detention pond. It is only 30' length going thru the embankment. The profile will slope up 4:1 to provide 2' of cover over 10' of the pipe, then slope back down 4:1. I planned on using a HW at the inlet and outlet end. When is anti-seep collar needed?
  7. kedpe

    Site work in a Michigan winter

    I just got a project near Coldwater,MI with an aggressive schedule. What aspects of site work can be done in a Michigan winter? I'm in central Ohio.
  8. kedpe

    Sizing fire supply pond

    How much volume of water is required for 130,000sf of building for a fire supply pond?
  9. kedpe

    Riprap at pond edge

    Hey guys-my first post: I've designed a fire supply and retention pond and called out 18" deep ODOT Type C (6"-18"; avg. 12") for the pond edges. The contractor wants to put #2 stone. Any experience? Thanks