Hi there,
I am working on an offshore project,sour crude and gas from the producing platform will be transferred to the onshore plant through a sub-sea pipeline network, theses pipeline need to be internally coated with FBE, one of the major issue which we faced on previous project is the...
Hi there,
I am working on an offshore project,sour crude and gas from the producing platform will be transferred to the onshore plant through a sub-sea pipeline network, theses pipeline need to be internally coated with FBE, one of the major issue which we faced on previous project is the...
HI,
I need to install a 26" flange on piping system designed for 5860 psig. ASME 16.47 is limited to CL 900 only, is there any standard for flanges above 24" for CL 2500?
Regards
Vassel
Hi there,
Is it safe to operate a 3 phase 380V,50Hz equipmment (including motor, UV dryers, PLC and some other auxiliary items) on 400V,50Hz supply? Similarly 220V,50Hz on 230V, 50Hz (single Ph)?
Regards
There is a concern raised from one the pressure vessel manufacturer, that the test coupon for the normalized material (A 350 FL2) shall undergo simulated heat treatment. As per my understanding, forgings are exempted from this requirement per section UG-11(a) and UCS-85 (e)(f) of ASME-VIII...
We need to purchase bronze valve for slops system, fluid is sour. Is it required for bronze valvs manufactured from ASTM B61/62 per MSS SP-72 to be NACE MR0175 compliant?
Thanks in advance for help.
Regards
Hi,
One of our client is asking to supply a 4" subsea ball valve in MEG (Mono-Ethylene Glycol) service with a design life of 50 years. Is it possible to have a valve for this much life (gurantee would be an issue I believe).
Thanks
Hi,
A storage vessel on an offshore platform to store Disulfide (DSO)/Dimethyl Disulfide (DMDS) is required, stored material is highly corrosive and flammable.
Can I use plain CS vessel or CS with Inconel 625 (or any other suitable material) cladding will be required?
MSDS is attached for...
Hi,
A storage vessel on an offshore platform to store Disulfide (DSO)/Dimethyl Disulfide (DMDS) is required, stored material is highly corrosive and flammable.
Can I use plain CS vessel or CS with Inconel 625 (or any other suitable material) cladding will be required?
MSDS is attached for...
Hi,
I am working on a PV having MDMT -58 degree F in wet sour enviroment, is SA-516-70 N suitable for this application? What is the minimun temp limit for SA-516-70N and where to find?
Regards
Hi,
I am working on a PV having MDMT -58 degree F in wet sour enviroment, is SA-516-70 N suitable for this application? What is the minimun temp limit for SA-516-70N and where to find?
Regards
Hi
I have a utility water tank,the hypochlorite package linked to this tank will produce O2 via the chemical reactions with organics in the water. There is no O2 scavenger feed. Tank material is A-516 -70
In this case, does the tank required some lining/coating to prevent corossion.
Thanks
Hi
I am working on an air cooled heat exchanger for glycol. This exchanger has 12 bays and each bay consist of two fan with motors, one motor is VFD compatable. I want to find out the turndown ratio for that motor. Min and max heat exchange required is 26,268 and 1,239 KW respectively. Max...
I need some info regarding design of API 650 tank with cone bottom, what code should be use along with 650? what type of bottom support will be required (Skirt or Legs)? and how much the slop will be? This is for SAGD water treatment application
Thanks