  1. fcxdfm

    hot tap natural gas piping

    I am working on a natural gas distribution project, and I am looking for some detail or procedure for hot tapping at the existing natural gas piping. The existing piping is 3" and 4" steel underground piping, and the new branch is 2" HDPE. Could anyone advise where I can find the detail or hot...
  2. fcxdfm

    FM200 with HVAC Smoke Damper

    Could anyone advise why the smoke dampers are required at HVAC supply and return duct for the electrical room protected by FM200 system? Which code should I refer to for this requirement? I am wondering if FM200 control panel can shut down the air-handling unit instead of smoke damper in case...
  3. fcxdfm

    Looped Natural Gas Piping Calculation

    I am working on a project to design an underground looped natural gas system with all branches networked together. I am looking for the software for pressure drop calculation and pipe sizing. Has anyone used or heard of any software for this use, or any other advise for the calculations? Thank...
  4. fcxdfm

    Natural Gas Pipe Sizing Software

    I am working on a project to design an underground closed loop natural gas system with all branches networked together. I am looking for the software for pressure drop calculation and pipe sizing. Has anyone used or heard of any software for this use, or any other advise for the calculations...
  5. fcxdfm

    P-trap at air-handling unit drain connection

    I had always thought that P-trap at the air-handling unit condensate drain connection is needed all the time, no matter if the cooling coil is blow-through or draw-through configuration. However, in the project I am working on, I select a wall-mounted BARD unit with blow through configuration. I...
  6. fcxdfm

    Reference Book - Natural Gas Distribution

    I am looking for some reference book for the design of the large scale natural gas distribution system. Could anyone give any advise? Thank you very much!
  7. fcxdfm

    RO Membrane Building - HVAC requirement

    I am working on the HVAC design for a new RO membrane building. Could anyone advise what's the typical indoor design criteria for the building? Does it require any strict temperature or humidity control? Or only some ventilation and anti-freezing heating(in north)? Thank you very much.
  8. fcxdfm

    Outdoor Ductwork Insulation

    In the project I am working on, the existing outdoor air-conditiong (heating and cooling) duct was insulated with 1-1/2" fiberglass and aluminum vapor barrier jacket. However, the insulation at the bottom of the duct always got wet after rain, and already become loose now only after a couple of...
  9. fcxdfm

    Humidity Control while Cooling the computer Room in Winter

    The computer room I am working on is in Houston. The winter outdoor design temperature 20 DB, and 60% RH are used. The space needs to be maintained at 75 +/- 5 Deg. F, and 50% +/- 5% RH throughout the year. The cooling load is about 6 ton and almost 100% sensible load. The outdoor air is about...
  10. fcxdfm

    Hydro Turbine Manufacturers

    Does anyone know any hydro turbine manufacturer in US? Thanks for help.
  11. fcxdfm

    Motor

    Anyone knows any motor can be driven by ultra high pressure water? Thanks.
  12. fcxdfm

    High Pressure Water Pump

    I am looking for a pump manufacturer, who can make high pressure water pump with 60,000 psi for jet cutting. The motor needs to be hydraulic driven. Thanks for help!
  13. fcxdfm

    OSHA Code for Rooftop air-handling Unit location

    Hello, everyone, I am working on a project, and need to locate several air-handling units on the rooftop. I heard before that OSHA code requires the rooftop unit cannot be located within 10 ft from edge of the building. Does anyone know if it is true? If yes, which section in OSHA address the...
  14. fcxdfm

    Automatic Fire Sprinkler System for Heath Hazard Storage

    Both Internation and Uniform Fire Codes require automatic fire sprinkler system for the heath hazard storage space (H occupancy). Can anyone explain why the automatic fire sprinkler system is still required, even when the hazard material is only corrosive (sodium hydroxide), and not flammable or...
  15. fcxdfm

    duct material for underground odor control

    What's the best duct material for the underground odor (H2S) control exhaust duct? FRP, HDPE or PVC schedule 80? The vacuum pressure of the exhaust system is about 5 inch... Thanks!!!
  16. fcxdfm

    FRP versus HDPE for Underground Sewege Odor Control Exhaust

    I am working on a odor control (exhaust) project for a waste water treatment plant. The underground duct needs to be 12" dia, and the air stream contains H2S. Shall I use FRP or HDPE for underground section? Any advantage to use HDPE instead of FRP? Thank you in advance.
  17. fcxdfm

    pressurization with exhaust louvers

    I am modifying an existing HVAC system serving a pump station in a waste water treatment plant. It has to be maintained at 0.1" WC positive pressure relative to the atmosphere. The room has existing exhaust louvers at exterior wall, and the client would like us to re-use them. Is it possible to...