  1. DivideByZero

    Is A-53 Type S fully replaced by A-106? Low Si Sulfidation

    Greetings fellow engineers, Some of you may be familiar with the problem low silicon (<0.1%) carbon steel presents in sulfidation services: unpredictable (and possibly much higher) uniform corrosion rates. Fortunately, A-106 has a minimum Silicon spec of 0.10%, which eliminates the concern...
  2. DivideByZero

    CS Tubesheet, 304 Tubes, 500degF

    Fellows, I am replacing an exchanger that has a carbon steel tubesheet and 1" 304 tubes. The shell side operates at 500degF. Besides service/corrosion concerns (we have those lined out), are there mechanical issues with the tube to tubesheet joint? I feel the difference in thermal expansion...
  3. DivideByZero

    API 661 Airfin - PWHT needed for new header nozzle?

    Greetings fellow engineers, I am supporting a project in which we will be adding a nozzle to an existing airfin heat exchanger designed to API 661. API 661, para 9.2.1 states "All carbon steel..headers shall be subjected to post weld heat treatment". I would like to understand the intent of...