  1. QC1971

    ASTM A536 70-50-05

    I have a question regarding the mechanical testing results for A536 70-50-05 material. I have a supplier who does both seperate and cast on samples however their acceptance criteria for cast on samples is significantly lower than what A536 specifies for 70-50-05. Where A536 calls for a tensile...
  2. QC1971

    Nozzle tie in welds

    Per section VIII Div 1 the first circumfrential joint falls under section VIII's juristiction. Is there any documentation required from the installer that makes the tie in welds similar to the U-1? Would making these welds be considered field assembly and need to be documented on the applicable...
  3. QC1971

    Hardness Testing

    When using a telebrineller it is recommended that the bar hardness be within 30 BHN of the expected material hardness. If there is a difference of 60 BHN between the bar and the test results would you expect the actual hardness of the material to be higher or lower than the test results?
  4. QC1971

    Hardness Testing

    When using a telebrineller it is recommended that the bar hardness be within 30 BHN of the expected material hardness. If there is a difference of 60 BHN between the bar and the test results would you expect the actual hardness of the material to be higher or lower than the test results?
  5. QC1971

    microstructure difference P9 vs P91

    What differences in microstructure can be expected between P9 (9Cr-1Mo) and P91 (9Cr-1Mo-V). I am familiar with the P91 as we use it in the power industry however I have heard very little on the P9 material as we do not use it.
  6. QC1971

    Listed Valves per NFPA 20

    Does NFPA 20 require that all valves be listed valves or just the valves that it specifically states the requirement of a listed valve?
  7. QC1971

    Hydro-test Gauges

    Does NFPA address the range of the test gauges? I have a contractor that wants to perform a 200 psi test using 200 psi gauges. ASME requires that the gauge be a minimum of 1.5 times the test pressure but I am not familiar with NFPA or its requirements.
  8. QC1971

    NFPA 20 Question

    In the 2003 edition of NFPA 20 para. 5.12.1.1 it states that indoor fire pump units shall be physically seperated or protected by fire rated construction. Are the fire pumps to be seperated from each other or from the rest of the building? I do not typically deal with NFPA and have had this...
  9. QC1971

    HDPE pipe inspection

    Can anyone help with the inspection criteria for welds in HDPE piping manufactured to ASME B31.1? I did have a chart for this but it has been several years since I have been involved with HDPE and I can not find it. Any help will be appreciated.
  10. QC1971

    Curie Temp. of SA335-P91 material

    I have a weld joint of SA335-P91 that is proving difficult to weld due to magnetisim in the pipe. can anyony tell me what the curie temp of this material is?
  11. QC1971

    ASME B16.5

    I need help with acceptance criteria for imperfections on the raised face gasket surface and the minimum depth of the serrations.