  1. KJvR

    Generator Steady State Fault Current

    This might be a dump question but I get lost every time I have to do something on a generator. I must calculate the steady state fault current (energy of fault) of a bus being fed by both the utility and two small 13 MW MV generators. I have the AVR settings. It states: "Current Limiter...
  2. KJvR

    CT Type for Earthing Transformer Protection

    I would appreciate any comment on the type of CT to be used for a Z-transformer (NEC / Earthing Transformer) protection scheme. The Earthing Transformer is connected to a generator bus and therefore needs separate winding protection. I will use delta connected CTs to prevent zero sequence...
  3. KJvR

    Cable Group Rating - IEC287 vs ERA 69-30 Part 3

    Hi, Does anyone have some experience with ERA 69-30 and how their derating factors were derived. I do not have access to this document. I have modeled some 11kV XLPE cables according to IEC287 and confirmed the values with the cable manufacturer. However, most cable manufacturers refer to...
  4. KJvR

    Overexcitation of induction motor/PFC combination

    Hi, I am currently designing a MV switchboard controling 3x500kW motors. PFC is done by connecting capacitors directly onto the 3.3kV busbar. Worst case scenario will be at least one stage (286kVAr) with one 500kW running with a trip on the incomer/11kV feeder. No load current of the motor...
  5. KJvR

    Surge Protection on Open Ended MV Cable

    I would appreciate any comments on the use of surge protection on open ended cables. I am doing a MV (11 kV) substation design connected to ring feeders that will be split during normal operating conditions. Long lengths of cables (up to 1500m) might be energised but not connected to a...
  6. KJvR

    Generator steady state fault current

    I would appreciate some help on determining the steady state fault current for Diesel Generators. The Diesel Generators (415V) is feeding through step-up transformers (Dyn - 11/0.4kV) onto an high impedance earthed 11 kV network (isolated from utility supply). The manufacturer provides the...