  1. snyper

    Combing flows before pumping

    I have two tanks, one with slurry, one with water. I wish to combine the fluids and feed a single centrifugal pump. The slurry flowrate is fixed, while water is added at a particular ratio to bring the mixture temperature and density below a set value. (Ratio is normally around 4 parts water to...
  2. snyper

    Flow through RO plate

    Hi all I have a water tank fed by a centrifugal pump. In the line between the pump and the tank inlet is an RO plate. I know the orifice diameter, and have all the pump data, line sizes, etc. How do I find what the flow rate into the tank will be? All the orifice calculations I come across...
  3. snyper

    Volume from pressure drop during hydrotest

    Hello Wondering if there is a quick formula to calculate volume of water lost from a pipeline under hydrostatic test, given a known drop in pressure and total volume in system. Test medium is water. Thanks