I have an application where a 316 stainlesss part is being used to maintain a compressive load on an assembly. During manufacturing, the SS part was heated to a point where the part relaxed and no long maintained a load on the assembly.
My question is at what temperature will the steel become...
I'm workig on a lubrication system and have to connect the tank to a manifold with a flexible connection. The connection or joint needs to withstand about a half inch of travel in any direction. Currently, the connection points are 3" ANSI B16.5 flanges.
The line/connection needs to include an...
Looking for some sparky knowledge here. I'm designing some test equipment and need to make sure I have enough contact area to prevent heating a threaded connection beyond the point where it can be reused.
We will be running 1000V and 1000A through the connection. The real trick is the duration...
I am trying to pick the best connection for some test equipment. I am running two copper axial leads (1.25" OD copper bar cut in half) down the center of a shaft. At both ends I will have a flat machined into the bars to accept a copper radial lead. The radial lead will thread into the axial...
I'm working on a lubrication system for a US military project and have had a little trouble sourcing 70/30 CuNi flanges, fittings etc. through a mfg that has experience with military projects. Can anyone point me in the right direction? Thanks.
PS..having some server issues and I apologize if...
I'm working on a lubrication system for a US military project and have had a little trouble sourcing 70/30 CuNi flanges, fittings etc. through a mfg that has experience with military projects. Can anyone point me in the right direction? Thanks.
Brian
I posted this question in the Fluid and Piping section but the responses I received related more closely to commercial plumbing.
I am looking to interface ss tubing with a bronze relief valve. I am not familiar with this brazing operation or even if it is an acceptable practice? The relief...
Working on a lube system for a military application and the pressure relief valve specifies a Sil Braze connection for the bronze valve. What is the best method for interfacing the valve with the 316 stainless steel tubing?
Brian
I am working on a military project and need to connect a lube line to a heat exchanger. The heat exchanger calls out a 1 1/4" ANSI B16.5 150# RF flange. The lube lines are 1 1/4" OD ss tubing with a 0.095" wall thickness. Can a flange be welded to this tubing for attachment? Is there generally...