  1. rota1

    Repeated Disaster Bushing Failure

    Hello everyone We have a between bearings Union centrifugal pump in a high temperature (700deg F) high viscosity service.After shop overhaul the disaster bushing failed during startup.The bushing was fused against the seal sleeve.This disaster bush is made of bronze and has a diametral...
  2. rota1

    Ruhr Pumpen pumps

    Hello all, Does anyone have experience with Ruhr Pumpen pumps particularly in hot hydrocarbon service?.Thanks
  3. rota1

    OB thrust bearings discolouring oil

    Hello all! we have here a Byron Jackson two stage, between bearings, boiler feed water pump that discolours the oil upon minutes of being put in service,bearings are skf 7409BG, and the driver is a motor running on a magnetic center.Coupling is a Waldron gear type, the spool piece has axial...
  4. rota1

    Sundyne pump model LMV 311

    Hi guys! Can you guys explain to me what in the design of this pump is so unique that allows for the high head and flow developed ? some one mentioned it is all in the discharge diffuser exit port?
  5. rota1

    Reducing Impeller Diameter

    Hi Guys! I have to reduce an impeller diameter. Should I cut both vanes and shroud or only the vanes. My thinking is only the vanes are to be reduced, maintaining impeller to cut water original clearance (Gap B).A strange school of thought has surfaced viz; that reducing the shroud eliminates...
  6. rota1

    single sealed vs shield ball bearings

    Hello everyone, This may seem as too basic a question but nevertheless, I am having a problem in understanding what is the difference if any, between a SEAL as opposed to a SHIELD bearing.
  7. rota1

    Motor Running above Overload point

    Friends, Please advise! We have here a two stage centrifugal pump, 157gpm capacity, at 995 ft head.This pump is in a water injection service supplying three streams, the flow is controlled via valves which are throttled to meet requirement. The motor driver is 100HP.According to the pump curve...
  8. rota1

    API Plan 23

    Hi guys! Please clarify? Here are two contradicting views on the clearances for the throat bushing in a API plan 23 environment overhung pump. One view is the throat bushing must be installed at the bottom of the seal cavity to help isolate the seal chamber from the pump flow, close clearances...