Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. minorchord2000

    ASCE 7-16 Section 12.14.3.2 The use of the overstrength factor

    Subsection 12.14.3.2.1, equation 12.14-9 specifies that Emh = 2.5*Qe. My question is when to use the 2.5 factor and when not to. The Code is unclear. I am designing anchorage forces for a vertical rigid steel storage tank and I use equation 15.4-5 to calculate the lateral seismic force, V...
  2. minorchord2000

    welded steel pipeline above ground thrust issues?

    I am a structural engineer and I have a question: I have a 24" diameter steel pipeline under about 40 feet of hydraulic head with occasional changes in direction of 45 degrees each. The pipes are welded together using groove welds. Do I need to account for thrust forces at the bends even...
  3. minorchord2000

    Full height concrete abutment walls subjected to scour

    We have been tasked to design full height concrete abutments on spread footings subjected to scour. The bridge structure will be an ACROW steel bridge similar to a Bailey bridge. The single span is 110 feet from CL bearing to CL bearing with HL-93 loading. My question concerns scour from...
  4. minorchord2000

    Pedestrian Bridge Horizontal Wind Load Application

    For a pedestrian bridge does the wind force calculated get applied to BOTH trusses or only the windward truss?
  5. minorchord2000

    Concrete Drilled Shaft Tip Elevations

    After determining the depth to fixity for concrete drilled shafts based on ADOT (Arizona DOT) Geotechnical Design Policy DS-3, how does one determine the tip elevation beyond the fixity depth? Is there a good rule of thumb (assuming that even exists) based on the shaft diameter?
  6. minorchord2000

    Drilled Shaft Tip depth beyond fixity depth

    After determining the depth to fixity for a concrete drilled shaft, what is the rule of thumb (if such a thing exists) for the increase in depth beyond fixity to the tip elevation?
  7. minorchord2000

    API 650 Tank Question

    I am tasked with designing a tank to hold acid (sg = 1.84) and one of the design criteria I have from the owner says: "Tank will be rated for 6" water pressure and -.4 oz vacuum." Can anyone shed some light on what this means? I am a structural engineer, not a mechanical engineer. The tank...
  8. minorchord2000

    Bridge Demolition Cost

    Hello: We have a bridge here in Tucson that might be scheduled for demolition due to its age and inadequate inventory and operating ratings. The bridge is a 6 span, non composite structure: total length = 363 feet: out to out width = 64 feet. Superstructure is composed of 4 feet wide...
  9. minorchord2000

    HS20 Wheel Load directly atop a concrete wall

    I am designing a narrow concrete trench with proprietary traffic rated grating which spans between the walls. The wall height of the trench is in the order of 5 feet and the wall thickness is tentatively 6 inches. When the wheel load of 16 kips + impact is directly over the wall, how does this...
  10. minorchord2000

    Renovating Box Beam Non Composite Deck to Composite Deck

    Gentlemen: I am analyzing an old 3 span non-continuous, pre-cast box girder bridge, with simple spans of 49.25 feet each. The superstructure is 27 feet wide and consists of 9 voided box sections 3 feet wide and 27" deep. Currently the driving surface is only about 2" of asphalt. Our scope of...
  11. minorchord2000

    Seismic Load on Ringwall Foundation

    I have a steel storage tank which is required to be anchored because the J factor exceeds the limit for unanchored tanks. I am using the AWWA code. It is 55 feet in diameter, 55 feet high and has an OTM of 14,436 ft-kips. The anchor bolt circle is 55.5 feet in diameter. I want to use a concrete...
  12. minorchord2000

    Ring Wall Seismic Design

    I have a steel storage tank which is required to be anchored because the J factor exceeds the limit for unanchored tanks. I am using the AWWA code. It is 55 feet in diameter, 55 feet high and has an OTM of 14,436 ft-kips. The anchor bolt circle is 55.5 feet in diameter. I want to use a concrete...
  13. minorchord2000

    Seismic vertical loads on concrete ringwalls

    I have a steel storage tank which is required to be anchored because the J factor exceeds the limit for unanchored tanks. I am using the AWWA code. It is 55 feet in diameter, 55 feet high and has an OTM of 14,436 ft-kips. The anchor bolt circle is 55.5 feet in diameter. I want to use a...
  14. minorchord2000

    Torsion at top of wall

    I have an existing wall about 15 feet high and about 30 feet long. The wall is 15 inches thick and any reinforcing is unknown. The owner wants to install a fall protection device at mid length along the wall which will provide a concentrated torsion of 90 in kips. What is a reasonable depth...
  15. minorchord2000

    Angle of Internal Friction

    I am structural engineer and have been tasked to design a rectangular bin hopper the contents of which is abrasive slurry with a specific gravity of 1.16. Can anyone give me the approximate angle of internal friction?
  16. minorchord2000

    Converting Non Composite Box Girder Topping to Composite Deck

    We are evaluating a 5 span concrete box girder bridge with an existing non-composite asphalt topping. After removal of the existing asphalt topping, can the proposed new 5" concrete deck be made composite with the existing concrete box girders. The bridge is 9 girders wide and the thickness of...
  17. minorchord2000

    Steel Water Tank Seismic Anchorage

    I have designed a 80,000 gallon water steel tank and I need some guidance on how to the anchor the tank to a concrete slab. There will 12 equally spaced anchors around a 20'-6" diameter tank. Seismic forces govern the overturning moment. The max uplift force is about 7 kips. I was thinking of...
  18. minorchord2000

    Building Enclosure Classification

    I am struggling to understand the provisions of ASCE 7-10 regarding the building enclosure classification. I think this provision of the code is poorly written. I have a rectangular building with both long walls completely open and both short walls solid masonry with no openings in the masonry...
  19. minorchord2000

    Calculation of Zero Movement in a continuous bridge

    I was reviewing a practice problem in the NCEES study manual about locating the zero movement location along a continuous bridge. The bridge is supported at the ends by expansion bearings at the abutments and by pinned bearings at the two interior piers. The span arrangement is 40'-120'-40'...
  20. minorchord2000

    API 650 Flat Roof Design

    I am a structural engineer and I am asking for assistance from the mechanical engineering community relative to the API 650 code. We are tasked with designing a flat roof (steel plate) for an acid reservoir with an internal diameter of 14 feet. When reading section 3.10 of the code, it...