Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: cfc
  • Content: Threads
  • Order by date
  1. cfc

    Braced Frames (Structural Steel) - Staggered Bolted/Bolted WF Beam To WF Column Web Connection

    I'm working on a traditional structural steel braced frame connection with a WF beam bolted/bolted with clip angles to the web of a WF column. Also included is a HSS shape diagonal welded to a gusset PL that has it's horizontal edge welded to the beam's bottom flange and the plate's vertical...
  2. cfc

    Composite Beam Anchor Studs Along Deck High Flutes

    A steel erector has asked to review a mezzanine project that involves recently installed composite beam framing where the steel anchor studs were installed along the deck's high flute. We have 3" concrete over 1 1/2"x18 ga composite deck (4 1/2" slab) with 3/4"x4" headed studs. In this...
  3. cfc

    Steel Bent Plate Versus Rolled Angle

    Assuming that a steel "L" shaped bent plate has the same dimensional properties as a rolled steel angle, are the structural strength capacities the same? I can see the bent plate having a slightly less strength if the "k" dimension is less but I don't believe that there is a process in place...
  4. cfc

    Single Plate Connection Using Long Slotted Holes

    Are long slotted holes prohibited for single plate connections if the holes are oriented normal to the design load? The AISC Steel Manual verbiage only addresses standard and short slotted holes but I can't find any LSDT holes prohibition. Furthermore, can a ST joint be used in this situation...
  5. cfc

    Wood Tread Structural Properties

    I'm designing steel stairs that are using bamboo, Brazilian Cherry or ash as the treads which are 10" wide x 2'-8" length. Is there a site where the structural properties for these species can be located? Or is it a situation where these species of wood are laminated over a structural grade...
  6. cfc

    Steel Joist Bearing Depth

    The typical bearing depth for a K-Series joist is 2 1/2". I have an alteration project where new joists will bear atop existing steel beams. I can add a new strucutral member atop the existing beams to achieve the standard 2 1/2" bearing depth. The other option is to specify a 3...
  7. cfc

    Steel Open Web Joists Lead Times

    I realize that this is soemwhat of a leading question(due to fabrication requirements, geography, project requirements, etc.) but in general are the lead times for open web joists longer than the lead times for rolled W shapes? TIA

Part and Inventory Search