  1. atmengr

    Acid Collection Vessel

    All, This a request for suggestions on available equipment for my idea. Hopefully I just don't know the availability and all of the experience in these forums can recommend something or have some other ideas... While draining and decontaminating equipment in a sulfuric acid alkylation unit, a...
  2. atmengr

    Updating Equipment Files/Documenation

    I'm coming out of my first turnaround as a unit engineer, and am looking at updating our documentation to reflect all the changes we made during the T/A, and information that was discovered during the planning and execution. I guess I'm looking for opinions on how the updates should be captured...
  3. atmengr

    SA-453 Gr. 660 Class C Code Allowed?

    Is SA-453 Gr. 660 Class C a Code Allowed fastener material under B&PV code? I have specified Gr. 660 bolting for an internal bolting application, and the vendor wants to use Gr. 660 Class C bolting, but states that it does not have code allowable stress values. Section II lists only Class A and...
  4. atmengr

    A-453 Gr. 660 Class C Code Allowed?

    Is SA-453 Gr. 660 Class C a Code Allowed fastener material under B&PV code? I have specified Gr. 660 bolting for an internal bolting application, and the vendor wants to use Gr. 660 Class C bolting, but states that it does not have code allowable stress values. Section II lists only Class A and...
  5. atmengr

    Twin Seal DBB Valve Pressure Relief

    Tried to search for this and talk with industry experts, but no conclusive answer so far.... A General Twin Seal valve, or a similar single body double block and bleed valve, often uses a device to relieve the pressure in the cavity between the 2 seals to the upstream (or downstream) side of...
  6. atmengr

    BFW System Bypass Valve Vibration

    Looking for advice in what we could be happening in our 650# BFW system, and how to correct it. We recently ran a parallel line to our current 650# BFW supply to our 650# steam drum. It is identical to the original line, which will be abandoned due to washed out CV and bypass globe valve. We...
  7. atmengr

    P&ID Rules about Flanges

    Don't know if this is correct forum to ask.... Are there rules about which flanges need to be shown on a P&ID (EFD, MFD)? I usually have only included flanges when they are: 1) First flange off of a piece of equipment 2) Blinding points 3) Flanged valves The question came up when I was...
  8. atmengr

    Out of Service Underground Piping

    Hi All, We have some underground piping that has been out of service for 4-15 years depending on who I talk to. The line has not been under pressure, and we are assuming it was not decontaminated (product was ~clean butylenes). We want to put the pipe back into its original service. I am...