Sirs:
It seems that SAP escalates the earthquake spectra for different damping values. If I enter a 5% damping spectra
and due to internal calculations of SAP (for example if I
use material damping) the modal damping of some mode results,say 8%,the program needs to escalate the spectra.
Does...
Sirs:
When SAP 11 and 14 is used for Seismic Modal Analysis there is an option to recover accelerations in different nodes. Option is called "Joint output acceleration", within "show tables".
Sap presents two alternatives: Absolute and Relative accelerations.When the option is used always...
Dear Sirs:
I am reviewing a seismic analysis of a vessel supported on four legs done with Compress. The legs are X braced ;the bracings are located at midheight of the legs.Thus,below the bracings and above the bracings there are segments of legs that are submitted to bending due to the...
Sirs:
I am looking for software graphics tools for developing an engineering application. The applic. considers an GUI for creating 3D models using
simple geometrical shapes. Once entered the solid model the software
performs some numerical calculations and presents the results.
Are such...
Sirs:
For nonmetallic piping,Heat Fusion Bonds the ASME B31.3
Acceptance Criteria requires non unfilled and unbounded areas.OK.But wich is the MANDATORY examination that the
erector have to perform to accomplish this,in case that the
contract only indicates that the piping shall be according...
Sirs:
I am planning to use a FE coupled model to analyse a large
tank for seismic forces,incorporating the tank contents.
Some multiphysics computer programs,such as ADINA,have
the capabilities of using fluid elements combined with
normal stress analysis FE.¿Does anybody has experience on...
Sirs:
I am preparing the seismic design criteria of a very
large bottom supported tank.Due to the size and importance of the tank I am thinking to use a coupled FE model that
incorporates the tank and its contents.With such a model
the hidrodynamic interaction I hope will be best accounted...
Sirs:
We are looking for an american company that provides
Field Inspection for HDPE large diameter pipes installation.
Our interest is to work with them for inspecting ,in Chile,many mining projects that are underway.Please help us
on finding this company.
Capablanca
Sirs:
I am looking for a software package that allows the following:
-I have a library of about ten typical steel towers models.
-Another library with 20 typical antennas.
The software shall be able to a)show a solid model of the towers,allowing rotations of the models and b)to pick
any...
Sirs:
This is a typical problem that presents in telecom
towers.I am refering to standard shear connections such
as between diagonals and goussets.These connections are
not slip critical and get loosened by the tower vibrations.
Eventually the bolts fall down.My interest is to knoww
an easy...
Sirs:
I am looking for software to calculate the mechanical
properties of thinwalled sections.I remember to have
seen such software for free downloading.
Thanks,Capablanca.
Sirs:
Does anybody knows if there is a problem to hot dip galvanize SAE 4041 anchor bolts.I have an opinion on this
that says that this treatment reduces strongly the strength
of the bolt.
Thanks,Capablanca.
I am interested in knowing more on the theory behind
Factor B in UG-23.It seems that is formula that accounts for buckling,thus reducing allowable compressive stresses.
Does anybody can help me on this?
Thanks,anyway.
Does it exists? A nontrivial,practical book explaining
gaps,slidelines,contact,elastoplastics ,FE formulations.Something like
Cook's "Concepts and Applications of Finite Element Analysis" but for non linear?
Telecom towers usually are overloaded with new antennae that increases the wind forces and reactions.Overturning of
the towers is one problem.The other is soil bearing stresses.For checking these last effects it is needed an in situ soil strenght evaluation that normally shall be done for many...
On electric transmission towers grillage foundations are
usual.But on telecomunication towers it seems not.Why is
this? The main restraint is similar:structures on hills where concrete transport is expensive.In many telecom steel towers I know the concrete was poured from an helicopter.Why not...
For rigid structures the ASCE 7,chapter 6 Wind Loads,
indicates a gust effect factor of 0.85.My question
is how a factor to account for a dynamic effect can
be less than 1.0? Thank for any info on this!