  1. Cuyanausul

    Acceptation acording to ASTM D3359

    We performed an "X" cut Adhesion test acording to ASTM D3359, with some results been clasified as 2A, and the standard does not say what classification can accepted. Please lead me to an acceptation criteria from 5A to 2A in a petroleum tank facility close to the sea
  2. Cuyanausul

    checklist

    Does any one have a checklit for AST API 650 tank inspection? I would aprecuate very much to get one please
  3. Cuyanausul

    Tank floor inspection

    Dear friends I haven´t been able to find in API 650 or 653 the tolerances for tank floor´s flatness, any one can help me?
  4. Cuyanausul

    pipe separation

    Hello Can anybody lead me to the separation for underground CS pipes acording to API please?
  5. Cuyanausul

    Pressure variatio on hidrostatic pressure

    Please lead us to a procedure to analize pressure variation while performing a pipe hidorstatic test, we will keep the operation pressure 24 hours and I need to know the relation due volume decrease/pressure increase. (I would say that the pressure will increase when the temperature decreases...
  6. Cuyanausul

    % x ray

    We are installing 4 lines for Gasoline, Diesel and LPG, and we are using ASME B31.4 for petroleum products and B31.8 for LPG, using 10% and 15% X ray testings respectivily, but I can´t find what would be the % after a weld is rejected? where can I find it? Thanks in advance
  7. Cuyanausul

    Aluminum trench covers

    Please urgent! I need a supplier for aluminum trench covers for a Hangar, similar to Neenah R-4990, haven´t been lucky with any manufacturer
  8. Cuyanausul

    Welding inspection

    Please tell me where to find the % of radiographic samples to take from a project, I have my AWS D1.1 but couldn´t find it. I also remember and always used 15%+15%+100% for every project, but I need to show it writen to a contractor.- Thank you
  9. Cuyanausul

    Vacuum test

    Hello Any one has experience on vacuum pipe test aproved by ASME code?
  10. Cuyanausul

    purlin welding

    How do you guys weld structural roof purlins end to end, or join them, I have done it with stick welding for years and I am sure this is not the best method, specially with 1/16" gage purlin, it takes a lot of time on my projects
  11. Cuyanausul

    100% Xrays

    Does any one have experience with a change in NDT for pipe welding in a contract by changing the % x rays from initial 15% to 100% aasked by the client. In our case due to the diameter of 48" and 36" the hidrostatic tests were not practical and the client decided this change. But... for us...
  12. Cuyanausul

    Late designs

    What would it be the latest aceptable design shedule for a project, is there any theory, some kind of regulation or standard.- We are finishing a project already overdue, because ( as we see it, tehre have been too many changes ), and our fixed costs are running, how do we convince the client...
  13. Cuyanausul

    Pipe cover

    We are finishing a geothermal pipe system and on top of the insulation we are covering with galvanized steel sheet, unfortunately we found out that they are stollen inmediately. Does any one have experience with a solution to stop steeling other than contracting guards over 10 kmts every 100...
  14. Cuyanausul

    Tolerance

    U R G E N T Please help me, we installed 16 bolts anchored to a concrete structure that will support a 17 tons tank, and no one noticed the bolts came with a smaller diameter, it was supposed to be 1 1/4" each and they actually are 1 1/8", I need to know where to find the tolerance for this...
  15. Cuyanausul

    Gasket

    Hello, I am will perform a flush in a geothermal pipe system and we will keep most valves installed, any idea for cheap provisional gaskets
  16. Cuyanausul

    maintenance pvc roof

    Hello, I am helping a company taht has a roof protected with a membrane that feels like pvc, be it or not, after 10 years it has become stiff and at some places is breaking ans the joints are going separated. Does any one have any recomendations on how to repair it?, I believe there are some...