  1. BADVE

    Regarding Factor of Safety

    What is the criteria for comparing Von Misses Stresses with Yield or endurance stress? How much factor of safety should be selected? Are there any guidelines to select FOS?
  2. BADVE

    Oxygen gas charging station

    I am engaged in a project that involves a portable oxygen vehicle for charging 350 bar oxygen into air craft (military application). can soem body tell me about the precautions athat are necesaary for handling oxygen ? Regards
  3. BADVE

    FEM of crankshaft with rolling elemnt bearings

    Dear All I am attempting FEM of a compressor crankshaft having ball bearings as main bearings. Can some body help me in modelling the bearing? What constraints are to be used for ball bearings (e.g. all dispacements blocked, all rotations are blocked ?) I would be grateful if somebody can...
  4. BADVE

    SOLAR ENERGY

    IN THE DAYS OF CONTINUEOUS LOAD SHADING FROM POWER SUPPLY AUTHORITIES IS IT POSSIBLE TO USE SOLAR ENERGY TO RUN A HOUSE WITH 5 KW CONNECTED LOAD? CAN ANY BODY THROW THE LIGHT OF UTILITY OF SOLAR ENERGY FOR COMMON MAN WHO WILL BE INDEPENDANT ON STATE POWER SUPPLY GRID?
  5. BADVE

    ULTRA DRY (DEW POINT MINUS 90 DEG C) NITROGEN STORAGE

    CAN SOMEBODY TELL ME ABOUT THE METHOD TO MAINTAIN A DEW POINT INSIDE CARBON STEEL CYLINDER AFTER ACHIEVING THE SAME BY USING A DESSICANT DRYER. ? does material of construction of cylinder critical to storage of ultra dry nitrogen ? what hose material is suggested for transfer of this ultra dry...
  6. BADVE

    STARTING OF DIESEL ENGINE THRO' CONTROL PANEL

    PL GIVE SOME TIPS TO MAKE STARTING OF DIESEL ENGINE WHEN THE SAME IS TO BE USED IN UNMANNED STATION & IS REQUIRED TO START AT POWER FAILURE.
  7. BADVE

    FAILURE OF MOTOR BY FLASHOVER IN STATOR

    IT IS OBSERVED THAT MOTOR HAS FAILED BY FLASH OVER IN THE STATOR. THE MOTOR WAS PROVIDED WITH TEMPERATURE SCANNER TO MONITOR & CONTROL THE WINDING TEMPERATURE. THIS PROTECTION COULD NOT WORKED. ANOTHER PROTECTION IS THROUGH MOTOR PROTECTION RELAY. HOWEVER THIS RELAY DO NOT COVER PHASE IMBALANCE...
  8. BADVE

    ELECTRICAL DRAWINGS

    How it is possible to make the electrical drawing for power circuit & control circuit in minimum time with the help of Autocad?