Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: russmech
  • Content: Threads
  • Order by date
  1. russmech

    Sight Glass Use in Refrigeration Piping

    Can someone tell me what the sight glass is actually used for in HVAC DX cooling refrigeration piping? Thanks.
  2. russmech

    New steam & condensate pipe flushing

    Can anyone give me an effective but simple way to clean/flush schedule 40 steel steam piping and schedule 80 steam condensate piping used in a small process steam application (100 psi, 2" pipe and smaller). I've seen references to open steam blowing and fresh water rinses, or simply wasting...
  3. russmech

    Lithium Bromide Double Effect HVAC Chiller Operations

    I am involved in the planning of a new chiller plant where the Owner is interested in using waste heat (steam) to feed absorption type chillers in the summer. We are in the far north where our season is short (long periods of chiller downtime) and chillers are usually not required at night...
  4. russmech

    BAC cooling tower information

    Does anyone have access to an old Baltimaore Air Coil (BAC) selection guide (book) for a VS series cooling tower? I'm trying to recommission a 1974 vintage VST cooling tower and have been unable to track down performance data for it. The factory (so I've been told) scanned their old catalogs...
  5. russmech

    Absorption chillers - low load performance

    Hello, I'm getting involved in the design of a chilled water plant (approximately 3000 tons)for HVAC cooling. Our location has a load profile with ALOT of cool temperatures 55F to 64F), so part load performance (of the total calcualated plant load) will be important. Because the chiller plant...
  6. russmech

    Pipe Insulation

    Does anyone know of a standard or reference that describes the maximum safe outside surface temperature of pipe insulation (for safety purposes)?
  7. russmech

    BTU Meters

    Can anyone give me a quick summary of their experience with BTU meters? Is a turbine flow meter better than electromagnetic or vice versa? Which is more reliable? Which is more accurate? My application will be heating loops only with propylene or ethylene glycol. Thanks.
  8. russmech

    Heat Transfer Consultant Needed

    Does anyone know of a Consultant or Firm that has expertise in calculating heat transfer and/or temperature profiles of a complex "fin"? Specifically, this application involves steel beams that penetrate a building's insulation envelope and are welded to structural steel. Preferably someone...
  9. russmech

    Heat Transfer Consultant Needed

    Does anyone know of a Consultant or Firm that has expertise in calculating heat transfer and/or temperature profiles of a complex "fin"? Specifically, this application involves steel beams that penetrate a building's insulation envelope and are welded to structural steel. Preferably someone...
  10. russmech

    return vs relief fan

    About a year or so ago, I read (and didn't finish) a good article of the relative merrits of return vs relief fans in HVAC systems. I now wish to read the article again but can't remember which magazine I read it in (I've since moved and had to clean out my magaizine collection. Does anyone...
  11. russmech

    Duct Pressure Classification?

    Can anyone tell me where I would find the definition of "medium pressure" ducting? I've looked in my SMACNA manuals and can't find it. Is this, perhaps, an outdated definition. Everyone uses the term, but I can't find a definition written down anywhere.
  12. russmech

    Rain falling speed

    Does anyone out there know how fast I would have to run air out a vertical open ended duct in order to overcome an average rain fall (and not rain into the duct). What are your sources or where should I look? Thanks.
  13. russmech

    Humidity Increase Due to Rainstorm

    I'm designing HVAC systems with humidity control for a museum and wish to know if someone can tell me or lead me to information on the short term effects of a passing thunderstorm. Project is in Fairbanks, Alaska where where summer temps and rainstorms could dramatically raise humidity levels...
  14. russmech

    infiltration as make up air

    Has anyone come up with a good way to tie an infiltration calculation (such as the ASHRAE "crack method") to the requirements for make up air due to a building's exhaust system? UBC gives an exception for combustion air if the room is large enough, but I've never been able to dream up...