  1. place1234

    US equipments move to China

    I'm having a question: We are having some equipments in US which to be moved to China. There is a power supply difference: US: 460V/60HZ CHINA: 380V/50HZ Searched a few articles about this equipments modifications. Any one here have any good suggestions?
  2. place1234

    SLC 500 Reference manual

    Can anybody tell me where to get a hard copy of SLC 500 Reference manual (instruction set)?
  3. place1234

    Current Transformer in VFD application

    Can a traditional Current Transformer be used in a VFD application? Is it capable to read correct current? For example , 10 HZ, 20HZ . A traditional Current Transformer I 've used normally works in a 50HZ application.
  4. place1234

    Power analyzer for inverter duty motor

    Hi, Which is the good power analyzer for inverter duty motor test ? Yokogawa is one, any body else? Txs.
  5. place1234

    VFD control method for back to back loading

    Sorry for my "broken" English again here:) My question is : I have two VFD driving two motors as back to back loading, that means one motor as test motor and another one as dyno motor ( also as generator). The principle is first start both test and dyno motor at full speed, they are running...
  6. place1234

    460/60HZ to 360V/60HZ

    How to convert a 3p/2HP/460v/60hz motor in applicaion 3p/2hp/360/60hz? Motor needs rewind, is it?How to calculate the rewind date based on the original winding data?
  7. place1234

    PT100 Question

    Having one Reliance motor, in the RTD specification they write: "PlATINUM,0.00392 TCR". I'am try using AllenBradley RTD input module , but as of the "input type selection", one is the 100PT(385), other one is the 100PT(3916). Which one shall select then to make the bit seeing in the channel...
  8. place1234

    VFD motor test equipment

    Dear all, I'm looking for information on VFD(inverter duty) motor test equipment. Is there any supplier making such equipment with auto report print, customrized test panel, etc? Or we have to build own test equipment? If so, that needs a lot of R&D. Help needed, thanks.
  9. place1234

    ALLEN BRADLEY PANELVIEW 2711-T9A2

    Somebody knew that what is the substitue for ALLEN BRADLEY PANELVIEW 2711-T9A2 as I was told that this model was obsolete now....many thanks.
  10. place1234

    motor design software

    Hi everyone Iam just curious about what kind of motor design software u r using? Can I have a hint ....
  11. place1234

    Inverter motor question

    I'm testing no load with VFD + Reliance inverter motor). Reliance motor information is below: 50hz/5HP/2915RPM/380V/FLA7.63A HZ RANGE: 5-50HZ. INVERTER TORQUE: CONSTANT INVERT HP VALUE: 3 INVERT NP AMPS: 5.3 CODE:J But when I started the VFD at 5 HZ, motor current was 8.5A. While my VFD...
  12. place1234

    core length of 182T frame

    Does NEMA specify the core length of 182T frame? if yes, what is the core length? tHX!
  13. place1234

    nema vs iec

    a NEMA TEXP motor convert to IEC, what is the code ? Any document to define this?
  14. place1234

    1hp 120v explosion proof single-phase motor

    I want to buy a 1hp 120v explosion proof single-phase motor, who is the good manufacturer? Anybody could recomment?
  15. place1234

    1000:1CONSTANT TORQUE

    An inverter duty motor normally says "1000:1 constant torque". what is the "1000:1"? Any standard like NEMA defines that? Look for your help, thx!
  16. place1234

    Circuit breaker

    I have a question about Circuit breaker. Cutler hammer Circuit breaker, 600V,15A, 100KAIC,3POLE. What does 100KAIC mean? 100KA inrush current? Sorry for I'm not experienced. I take this BBS as my teacker:)
  17. place1234

    inverter duty motor

    I have a Reliance inverter duty motor, on the report , there writes: duty HP RPM AMPS VOLTS HERTZ CONT 400 1150 445 575 58 CONT 400 2400 387 575 121 My questions are : 1. why 58herz? This motor is for China market, so the base frequencey should be 60herz? 2. why...
  18. place1234

    About NEMA control signal lead (letter "C") for DC motor

    I'm quite new to DC motor application and wanna learn a lot. Anybody could tell me how does the control signal lead (NEMA letter "C", between Intercoil and armature) work? To what it connect? Why call it control signal?
  19. place1234

    iec standard

    Does anyone knows the iec standard number that defines frame designation, cooling method for polyphase motor? Thanks.
  20. place1234

    invertter motor load test stand

    Hi everybody, We are thinking setup a load test stand for inverter duty motors. Put one inverter motor as the dyno, the test motor coupled with this dyno motor. Both motors controlled by two VFD drives. This should work in theory, But practically a few questions I need to know. 1. When the test...