  1. trivedi123

    Anybody has come across cantilever

    Anybody has come across cantilever racks design in seismic zone, appreciate any input. thanks
  2. trivedi123

    I am looking for ROM cost for class

    I am looking for ROM cost for class 5 concrete specified in ACI to get finish of FF 35 and FL 25 numbers. Appreciate any help. Thanks
  3. trivedi123

    structural general

    I have come across structural member "6B20" from old drawing. Anybody knows section properties for this member ?
  4. trivedi123

    slope transion for road

    What is "( slope transition"? Where and how do I verify this requirement? It is at road intersecting each other or road changing direction or changing width. from two lanes to one? Any help? Is it different than longitudinal slope?
  5. trivedi123

    Vertical curve verification

    I have transporter requirement for vertical curve is 7.5" in 50'. I have A&E report showing profile of vertical . I need help to verify requirement. Attached is the profile. Any help will be appreciated...
  6. trivedi123

    Vertical drop in roadway

    How do I provide transition between two roads with elevation difference of 5'. My transporter can accommodate 7.5" drop in 50' length. Roads intersect at 90 degree and I don't have enough horizontal distance available for vertical curve to accommodate 5' drop. Is there any way method to...
  7. trivedi123

    crawler crane

    I am looking for some guidance on crawler crane. Customer wants to use crawler crane on 12" thick concrete slab on grade with soil bearing pressure of 3000PSF.Crane can put a load of 4000psf on concrete slab. Is there any specific design requirement to check slab for crawler crane load?
  8. trivedi123

    road estimate

    I am not a civil engineer and need some help in cost. Is there any way we can estimate the 24' wide street with 24" dia. culvert pipe/mile? Appreciate any help. Thanks
  9. trivedi123

    Cribbing under crane outrigger feet or chock feet

    I need at least3'x3' cribbing under outrigger pad to transfer the load to supporting slab Question is if feet has rubber (with ribs like car tires) pads as load transferring surface, the damping can reduce impact load or the cribbing requirements? Thanks for help.
  10. trivedi123

    Pouring the opening in existing slab

    I need to fill the approximate 3'x3' opening in existing slab. The slab is designed for 25 psi ultimate loading and is 9" thick with #6 rebar's T/B each way. Any suggestion for designing the area? I can drill and use dowels in existing slab but area is small for matching existing reinforcement...
  11. trivedi123

    Grade change without vertical curve

    thread194-36445 I have not work on roads but come across problem with 50' curve with 7> grade without vertical curve. designer come up with 7.5" vertical height from low point to high point. Is anybody can show me how this calculated/ I saw 1% incoming and 1.5% outgoing slope on 20M curve shows...
  12. trivedi123

    Pipe penetration fill to withstand the pressure of 3.5 psi

    I have pipes/conduits penetrations core drilled in blast/containment wall up to 5" dia. Anybody come across to seal the penetration subjected to 3.5 psi pressure? Temporary or permanent solution. I will appreciate any help.
  13. trivedi123

    Road smoothness

    Any one has come across road smoothness requirements, 1/4" in 10' and 1/8" in 1'?
  14. trivedi123

    transverse slope on highway

    anybody has any idea of safe transverse (perpendicular to traffic direction)slope for highway?
  15. trivedi123

    concrete insert design

    I have to design male and female concrete epoxy inserts with tension and shear load applied at top of anchors. Do I need to check the wall of outer insert for shear.
  16. trivedi123

    Special details due to seismic condition

    I am trying to make opening in existing non loadbearing block wall in seismic zone building to bring some equipment inside the building and after close the opening. Do I need to provide any special details due to seismic condition? Thanks