  1. HenryOhm

    Probability Distribution of Transformer Inrush

    Hi All, I was just curious if anyone has any better or contradictory information on transformer inrush probability than this excerpt I found (out of a PhD thesis by Jinsheng Peng, "Assessment of Transformer Energisation; Transients and Their Impacts on Power Systems", Pg. 174): "Furthermore...
  2. HenryOhm

    690V Motor Cable Insulation off Microgrid

    Hi All, I have worked with two large system integrators on 4-5 different projects the last few years. They have competing views of cable insulation for 690V motors operating off VFD. One recommends a specific VFD cable with 2000V rating, three symmetrical ground wires, shield, etc. The other...
  3. HenryOhm

    Good Book on AFE PWM Drives?

    All, My textbook "Power Electronics: Converters, Applications and Design" by Mohan/Undeland/Robbins has served me well for over 20 years. I've used it for DC drives, LCIs and through to PWMs. It does have fairly good coverage of an AFE's use to interface to a grid. The DC bus voltage of Vd...
  4. HenryOhm

    T'do Under Short Circuit with AVR Trip of Generator

    All, I am on a project where the systems integrator is proposing an AVR trip for generator short circuit rather than generator OCPD trip. I am concerned about the implications for arc flash incident energies and the time it would take for: 1) the control system to recognize the fault...
  5. HenryOhm

    Arc Flash, IEC 61641 "Arc Free" and NFPA 70E / IEEE 1584

    All, To the best of my knowledge, North American standards like NFPA 70E and IEEE 1584 regarding arc flash have no equivalent to IEC 61641 for "arc ignition protected zones". I understand the IEC used to refer to this as "arc free". In Section 1 (Scope) of the IEC 61641, it ends with the...
  6. HenryOhm

    Inrush on Primary of Three-Winding Transformer When Other Two are In Use?

    I am working with an energy storage application. A three-winding transformer is in use. The utility feeds the primary winding medium voltage. One low-voltage secondary feeds an energy storage inverter with lithium-ion behind it. The third winding steps down the utility power and feeds a...
  7. HenryOhm

    Motor List Price Multipliers and $/kW at 1000kW

    I am making a speadsheet/chart of different motor costs to the end user (industrial). I used catalog list prices from ABB/Baldor for primarily 6-8 pole machines, TWMC for larger medium voltage and Lafert and Toshiba for PM motors. I also added a curve from USDOE for a more common type, not...
  8. HenryOhm

    Typical Subtransient Reactance for Smaller Synchronous Generators?

    All, I know this has been discussed before in more general terms. Referring to the IEEE Std 141 typical reactance values, they list xd" as 0.16 per unit for 12 poles or less (salient-pole with damper windings). In my experience with low-voltage diesel-driven 4-pole gensets in the 100kW -...
  9. HenryOhm

    Voltage Suppression for 19H 50A DC Motor Field

    I have a project involving large 7000Hp DC motors with 19H fields with a resistance of about 5ohm. They normally need around 20-50A of field current for most all operating scenarios. Currently, the system has selenium suppressors installed for overvoltage suppression if the exciter suddenly...
  10. HenryOhm

    Wye-Delta Transformer Feeding 6-pulse SCR Exciter

    I am investigating possible arcing of connections on the primary side of a wye-delta transformer feeding a 6-pulse, three-phase SCR-based exciter. The arcing led to a small electrical fire so there isn't a lot of evidence left of where things might have started. The transformer is 18kVA and...
  11. HenryOhm

    Transformer Percent Impedance with 120 vs 240V Dual-Voltage Outputs

    All, I have a 480:120/240V single-phase transformer. The secondary side has the standard four wires out and are wired in parallel to only put out 120V. The transformer nameplate says "Percent Imp (2) 2.8" and it is 15.0kVA. Does the "(2)" in the first nameplate suggest that the % imp is...
  12. HenryOhm

    PE Stamp of MV Swbd Test Procedures?

    I am being asked to supply test procedures that I have used to test relay logic wiring on MV Switchgear for a publicly posted follow-up bid process. I only shared these with people inside our company until now and the previous swgr was tested only with my full attendance and oversight This is...
  13. HenryOhm

    24VDC control and power in same cable and NEC 725?

    Sorry, this is probably a bit obtuse. I have a multi-conductor 600V rated cable running from a switchboard to an excitation panel. The cable uses only four of the 14AWG wires in it for switching a relay in the panel and two other feedback contacts to the switchboard, numerous other spares in...
  14. HenryOhm

    Arrester Failue Mode in High-Resistance Grounded or Floating Systems

    All, We have a 4160 island power system that is high-resistance grounded (broken delta PT tertiaries only on one common bus switchgear cubicle, not each cubicle set of PT's, alternators actually floating). The switchgear has vacuum breakers and so came with small surge "limiters" that were...
  15. HenryOhm

    Arc Flash Energy in Medium vs Low Voltage Systems

    I've noticed in some fault current and arc flash studies I've seen lately, that the low voltage systems produced higher incident energies (cal/cm2) than those for medium voltages of similar power levels. My sample size is probably just too low and I know that it is probably quite complex. I am...
  16. HenryOhm

    Better Options than Meggering for 4160V Alternator?

    All, We have a 4160V, ~3MW diesel genset that went through some bad juju with arcing in the entrance cubicle of its attached switchgear cubicle. Previous loss of PT fuses on shutdown led the voltage regulator to take it very high on ramp up from idle to rated (perhaps as high as 150% and for a...
  17. HenryOhm

    Large 8-pole induction motor for slow speed application

    All, I am investigating the upgrade of an old 5,000Hp 150rpm DC motor to AC for a pump application. Am curious about an "off-the-shelf" induction machine operating off PWM versus synchronous due to up-front price. Appears that an 8-pole induction machine is not stretching this too far but...
  18. HenryOhm

    Avoiding Motor Insulation Breakdown via PWM VSI

    All, I have read some whitepapers that indicate that IEC 60034-18-41 & -42 are superior to American standards NEMA MG 1, Section 31, IEEE 522, etc when it comes to helping avoid premature insulation breakdown of motors downstream of PWM VSI's: "New IEC standards for qualifying stator...
  19. HenryOhm

    Current ripple on DC Motor fed by Synchronous Genset with 6-pulse SCRs

    All, We are looking at upgrading an old Ward Leonard loop with DC gens to AC synchronous generators. The DC motors involved would be retained. We are a remote operation with utility power an impossibility. I am trying to estimate what levels of ripple current one would expect from ~1600kW...
  20. HenryOhm

    Transformer Inrush and Frequency of Breaker Closures

    All, Could anyone suggest any industry standards or otherwise as to the maximum energizations per time frame one should limit oneself to with transformer inrush? Will be doing some testing soon involving four identical 2800kVA three-winding transformers, 600:375:375VAC, with multiple breaker...