Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: reena1957
  • Content: Threads
  • Order by date
  1. reena1957

    Bypass for big sized Control valves

    Hi,We are designing one of the biggest units which has control valves of size 20inches and above. The in-house standards do not allow globe valves on the bypass as they are very big but only allow gate valves which will not help in throtlling the flow. One solution suggested is to go for two 50%...
  2. reena1957

    MDEA Amine regenerator unit filters-propritary vs conventional

    Dear All, Currently we are designing a MDEA Amine regenerator unit. The Amine is coming from VGO Hydrotreating ubit with 0.4mole Hes loading.We are doing the conventional filter system(Mechanical 5 micron pre and post filters ad Carbon filter on a 10% side stream-only 5% thru carbon) but are...
  3. reena1957

    Not Considered items in Hazop study??

    Friends, I recently came across a HAZOP study which included the following in NOT CONSIDERED list: 1. Failures of Manual valves 2. Operator Error 3. Passing of NRVs and PSVs Is it OK? Pl give your views. Thanks in advance.
  4. reena1957

    Any design tips for better friendly troublefree MDEA Amine Regen unit?

    Guys, thanks for responding to my last query on MDEA max reboiler temperature. But will anybody help with some info OR articles/ references on design tips for MDEA regenerator improved friendly troublefree operation?? Thanks in advance
  5. reena1957

    MDEA reboiler Maximum Steam temperature

    We are in the process of designing a MDEA regeneration reboiler. What is the max heat flux and what is the allowable Delta T? Can MP steam (about 180 Deg C) be used for heating? Thanks in advance!! Note.This was inadvertantly posted first in Chemical environmental Control forum first. Pl reply...
  6. reena1957

    What is the reboiler steam temperature for MDEA amine regeneration ?

    We are in the process of designing a MDEA regeneration reboiler. What is the max heat flux and what is the allowable Delta T? Can MP steam (about 180 Deg C) be used for heating? Thanks in advance!!
  7. reena1957

    Unit Fire area for relief quantity calculation

    While it is clear how to design relief for a single equipment for Fire case, What will be the basis for sizing the relief header from a process unit consisting of only liquid filled vessels and only case is fire case for each of the PSVs? In short, do we take one vessel or multiple vessels under...
  8. reena1957

    SPARGER DESIGN FOR A CUSTIC TANK MIXING

    Can somebody give some idea on how to get the air flow required for sparger mixing of caustic in a tank. Sparger design procedures demand the air flow first. But how to get that flow? Thanks in advance
  9. reena1957

    MDEA treatment of Recycle gases from hydrotreating units

    Can somebody give some suggestions for a good simulator package for MDEA absorption and regeneration for treating recycle gases from various Hydrotreating units? and if FCCU gases are also treated by the same amine unit? I have already seen the earlier threads but anything new will be...
  10. reena1957

    Liquid Seal at the outlet from condenser to accumulator?

    Hi All, We have a P&ID showing a liquid seal (an inverted U) at the outlet from a Overhead(OH) condenser to the accumulator below. The accumulator is having a split range fuel gas/flare pressure controller. The flow is by gravity from the condenser to the accumulator as there is a pressure...
  11. reena1957

    How OR do we flush a thermic fluid heater when we cut flow to exgrs?

    Hi all, We have a thermic fluid heater in the system design. The heater is cut off and and the flow to heat exchangers are cut in case of plant emergencies. what do we do to protect the thermic fluid heater coil? Do we flush the coils with inert gas? Heater Vendor has not given any...
  12. reena1957

    Which is best? Vaporization in last exchanger or Control Valve?

    Hi, I am in a dilema: Where should I put my Flow Control valve controlling feed flow to the column? At the outlet of a preheat exchanger or at the inlet of exchanger. The liquid is getting heated close to its bubble point in the exchanger and might start vaporizing if there is no CV downstream...
  13. reena1957

    Pressure control for Net Zero vapor generation system

    Hi, I have to choose a Pressure control for Net Zero vapor generation system with no light components - sort of kerosine splitter. I have the "Steady under pressure - pressure control techniques" by Sloley giving 26 different methods with plus and minus for each scheme. But I would like to know...
  14. reena1957

    Stabilization of Light crude in Wellhead locations

    Guys, this might not be the right forum but still being a refinery person forced to work on a wellhead crude stabilization project simulation, I want to know how to reduce the RVP of light crude to about 5psig using only gas-oil separators? In refinery stabilizers, we always went for a...
  15. reena1957

    Liquid hydocarbons from waste plastics(PE&PP)

    Hi, Is there some free literature on the above? Any working plants by reputed big companies? I have read abstracts of a few papers but nothing giving much details? Someone is trying to sell our refinery a visbreaker cum Vacuum distillation followed by hydrodewaxing process to produce diesel out...
  16. reena1957

    Olefins removal by Acid treatment?

    Hi, Can anyone help me whether Olefins in C6 -C8 range can be removed by strong sulfuric acid(95%) treatment? We tried in laboratory to do this with 95% H2SO4 on a 96% pure(rest paraffins&Olefins&cyclos) Toluene cut and we could not get any aqueous phase separation We were trying to get pure...
  17. reena1957

    Olefins removal by strong acid treatment?

    Hi, Can anyone help me whether Olefins in C6 -C8 range can be removed by strong sulfuric acid treatment? We tried in laboratory to do this with 95% H2SO4 on a 96% pure Toluene cut and we could not get any acqueous phase separation.Where did we go wrong? We cannot afford Hydrogenation.
  18. reena1957

    Waste plastics to hydrocarbons?

    Is there some free literature on the above? Any working plants by reputed big companies? I have read abstracts of a few papers but nothing giving much details? Someone is trying to sell our refinery a visbreaker cum Vacuum distillation followed by hydrodewaxing to produce diesel out of molten...

Part and Inventory Search